5.8 Surge Protection Test (Current Input, CH1)
Use the following instructions to perform surge test on the current input channel-1:
1. Set dual polarity regulated power supply to +15 V : 0 V : –15 V and apply the power at connector J2
2. Install jumper J6 in 5–6 position to connect 249 Ω as burden resistor
3. Set the source meter to 20 mA and connector to PSIL116 at J1
4. Use UCS500N to generate surge pulses. Set the test voltage to ±1 kV and coupling impedance to 42 Ω as
specified by IEC61000-4-5 to check the signal line transient immunity
5. Connect the surge pulse generator UCS500N at J1 and enable it
6. Observe the waveforms using an oscilloscope
show surge performance for current inputs with TPS26610 on the TPS2661EVM
eFuse evaluation board.
Figure 5-13. IEC61000-4-5 (+1 kV, 42 Ω) Signal Line Surge Immunity With TVS3301 at Input of CH1
Test Setup and Procedures
18
TPS2661EVM: Evaluation Module for TPS2661x
Current-Loop Protector
SLVUBX8B – OCTOBER 2020 – REVISED DECEMBER 2021
Copyright © 2021 Texas Instruments Incorporated