General Configurations
4
SLVUAV3A – August 2016 – Revised February 2017
Copyright © 2016–2017, Texas Instruments Incorporated
TPS26600-02EVM: Evaluation Module for TPS2660x
4
General Configurations
4.1
Physical Access
lists the TPS26600-02EVM input and output connector functionality,
describes the test
point availability, and
describes the jumper functionality.
Table 2. Input and Output Connector Functionality
Connector
Label
Description
T1
CH1
VIN1(+), GND(–)
CH1 input power supply to the EVM
T2
VOUT1(+), GND(–)
CH1 output from the EVM
T3
CH2
VIN2(+), GND(–)
CH2 input power supply to the EVM
T4
VOUT2(+), GND(–)
CH2 output from the EVM
Table 3. Test Points Description
Channel
Test Points
Label
Description
CH1
TP1
FLTb1
CH1 fault indicator
TP2
VIN1
CH1 power supply input
TP3
VOUT1
CH1 output voltage
TP4
SHDNb1
CH1 shutdown input
TP5
IMON1
CH1 output current monitor
TP7, TP8, TP9
GND
GND
CH2
TP10
FLTb2
CH2 fault indicator
TP11
VIN2
CH2 power supply input
TP12
VOUT2
CH2 output voltage
TP13
SHDNb2
CH2 shutdown input
TP14
IMON2
CH2 output current monitor
TP16, TP17, TP18
GND
GND
Table 4. Jumper and LED Descriptions
Jumper
Label
Description
J1
J1
CH1 fault LED pulled to VIN1, if installed
J2
J2
CH1 output power indicator LED pulled to VOUT1, if installed
J3
J3
CH1 bulk output capacitor connects to VOUT1, if installed
J4
MODE
CH1 MODE selection
spac
1-2 position sets latch-off mode
spac
2-3 position sets auto-retry mode
spac
Open position sets circuit breaker with auto-retry mode
J5
ILIM
CH1 current limit setting
spac
1-2 position sets 2.23 A
spac
3-4 position sets 1.5 A
spac
5-6 position sets 1 A
spac
7-8 position sets 0.2 A
J6
UVLO
CH1 UVLO setting
spac
Sets internal UVLO (15 V), if installed
J7
OVP
CH1 OVP setting
spac
Sets internal OVP (33 V), if installed
J8
J8
CH2 fault LED pulled to VIN2, if installed
J9
J9
CH2 output power indicator LED pulled to VOUT2, if installed
J10
J10
CH2 bulk output capacitor connects to VOUT1, if installed