General Configurations
Figure 3. J3= No Jumper Current Limit (1.5 A) Test Auto Retry (CH1)
4. Set the output load at 5.0
Ω
±0.5
Ω
on CH2 and then enable the load. Turn on the VIN2 power supply
and verify that input/output current is limited as per the setting in
. Verify the device is in
latched-off mode and that the FLTb2 RED LED (D7) turns ON as shown in
. The level of the
current pulse should match with the load current limit (based on the respective jumper setting) as
shown in
Figure 4. J7 = No Jumper Current Limit (1.5A) Test with Latch (CH2)
5. Set the input power supply to zero volts and disconnect all equipment from the DUT.