4.3 MSP-EXP430FR5969 Details
The TPS23882B1 accepts the MSP-EXP430FR5969 evaluation module when the application requires
management of the TPS23882B1 devices with an external controller.
1. Install MSP-EXP430FR5969 onto BOOST-PSEMTHR8-097 and ensure that the USB2ANY ribbon cable is
NOT installed into J2.
2. Connect the PC to the LaunchPad as shown in
.
3. The source code was developed for the MSP430 LaunchPad Development Kit (MSP-EXP430GFR5969)
using the Code Composer Studio
™
(CCS) version 7.2.0 development environment. The target MSP430 can
be programmed within this environment.
4. Once CCS is installed, use the basic set of instructions listed in
the project. CCS version 7.2.0 is used in the following examples. Note that a terminal program such as
HyperTerminal or Teraterm is required to view the output from the EVM when it is running.
4.3.1 Basic CCS and Terminal Setup
Use the following steps for basic CCS and terminal setup:
1. Launch the CCS program on the PC:
Start
→
Texas Instruments
→
Code Composer Studio 7.2.0
→
Code
Composer Studio 7.2.0
.
2. OK the workspace location and CCS starts.
3. Import the project:
Project
→
Import CCS Projects
(make sure you are in CCS Edit mode).
4. Navigate to the project location, then click the
Finish
button.
5. Build the project by clicking the hammer symbol. Semi-Auto or Auto mode can be switched selected using
the drop-down arrow to the right of the hammer symbol.
6. Launch the debug session from CCS to activate the current project: Run, Debug (or F11).
7. Run the active project: Run, Resume (or play button, F8).
8. Determine the PC COM port connected to the LaunchPad by going into the
Device Manager Ports
(COM
and LPT) section. Launch the terminal program.
9. Once the terminal program is properly connected to the LaunchPad running the PoE firmware, then text
similar to the following image appears.
Figure 4-6. Semi-Auto UART Transmission Startup
10. The TPS23882B1 is now waiting for a PD load to be installed. As ports are installed, the system
automatically detects, classifies, and powers up the port as shown in
on the screen approximately every 10 seconds.
TPS23882B1 GUI Setup
14
TPS23882B1EVM: PoE, PSE, TPS23882B1
Evaluation Module
SLVUC36 – APRIL 2021
Copyright © 2021 Texas Instruments Incorporated