Follow these steps when using the TPA6101A2 EVM with the TI plug-n-play
audio amplifier evaluation platform (see the platform user’s guide, literature
number SLOU011, for additional details). Numbered callouts for selected
steps are shown in Figure 2–1.

-

Platform preparations

1) Ensure that all external power sources are set to OFF and that the platform

power switch S1 is set to OFF.

2) Install a TPA6101A2 module in platform socket U5, taking care to align the

module pins correctly.

3) Use switch S2 to select or bypass the signal conditioning EVM (U1).

4) Set control signal polarity jumper JP7 to Lo.

5) Set Hp source switch S3 to U5 to route the output signal to the headphone

Jack (J10).

-

Power supply

6) Select and connect the power supply:

7) Connect an external regulated power supply set to a voltage between 1.6

V and 3.6 V to platform V

DD

 power input connector J6, taking care to ob-

serve marked polarity,

or

8) Install a 3-V to 5-V voltage regulator EVM (SLVP097 or equiv.) in platform

socket U6. Install a 9-V battery in B1 or connect a 7-V to 12-V power
source to a platform V

CC

 power input J1 or J2 and jumper the appropriate

power input (see platform user’s guide). Set jumper JP1 on the SLVP097
to 3.3-V operation.

-

Inputs and outputs

9) Ensure that signal source level is set to minimum and that potentiometers

R1 and R4 are set to the midpoint.

10) Connect the audio source to left and right RCA phono jacks J3 and J5 or

stereo miniature phone jack J4.

11) Connect 16-

 to 32-

 headphones to headphone jack J10.

-

Power-up

12) Verify correct voltage and input polarity and set the external power supply

to ON. If V

CC

 and an onboard regulator EVM are used to provide V

DD

, set

platform power switch S1 to ON.

Platform LED2 should light indicating the presence of V

DD

, and the evaluation

modules installed on the platform should begin operation.

Summary of Contents for TPA6101A2

Page 1: ...TPA6101A2 Audio Power Amplifier Evaluation Module 2001 Mixed Signal Products User s Guide SLOU104A...

Page 2: ...esign TI does not warrant or represent that any license either express or implied is granted under any patent right copyright mask work right or other intellectual property right of TI covering or rel...

Page 3: ...ngs This book may contain cautions and warnings This is an example of a caution statement A caution statement describes a situation that could potentially damage your software or equipment This is an...

Page 4: ...grated circuit FCC Warning This equipment is intended for use in a laboratory test environment only It generates uses and can radiate radio frequency energy and has not been tested for compliance with...

Page 5: ...3 1 3 TPA6101A2 EVM Specifications 1 3 2 Quick Start 2 1 2 1 Precautions 2 2 2 2 Quick Start List for Platform 2 3 2 3 Quick Start List for Stand Alone 2 4 2 4 Reference 2 5 2 4 1 TPA6101A2 Filterless...

Page 6: ...1 Quick Start Platform Map 2 2 2 2 Quick Start Module Map 2 4 2 3 TPA6101A2 Class D EVM Schematic Diagram 2 5 2 4 TPA6101A2 EVM Top Layer 2 6 2 5 TPA6101A2 EVM Bottom Layer 2 6 Tables 2 1 Typical TI P...

Page 7: ...Instruments TI TPA6101A2 audio amplifier evaluation module SLOP336 It includes a list of EVM features a brief illustrated description of the module and a list of EVM specifications Topic Page 1 1 Fea...

Page 8: ...y Configuration With the TI Plug N Play Audio Amplifier Evaluation Platform J Evaluation module is designed to simply plug into the platform automatically making all signal control and power connectio...

Page 9: ...e TI plug n play audio amplifier evaluation platform or to be wired directly into existing circuits and equipment when used stand alone The platform has room for a single TPA6101A2 evaluation module a...

Page 10: ...1 4 Introduction...

Page 11: ...irectly into existing circuits or equipment The platform switch and jumper settings shown in Table 2 1 are typical for the TPA6101A2 EVM and will cause the TPA6101A2 IC to shutdown mute when a plug is...

Page 12: ...m or both may result Figure 2 1 Quick Start Platform Map Signal Conditioning CAUTION Do not insert or remove EVM boards with power applied ICC JP4 F1 VR1 R1 JP3 JP2 JP1 AC DC J2 VCC J1 D1 D2 D3 D4 J2...

Page 13: ...upply set to a voltage between 1 6 V and 3 6 V to platform VDD power input connector J6 taking care to ob serve marked polarity or 8 Install a 3 V to 5 V voltage regulator EVM SLVP097 or equiv in plat...

Page 14: ...laced with the code TIAJM Power supply 1 Ensure that all external power sources are set to OFF 2 Connect an external regulated power supply set between 1 6 V and 3 3 V to the module VDD and GND pins t...

Page 15: ...101A2 EVM Schematic The TPA6101A2 EVM schematic is shown in Figure 2 3 Figure 2 3 TPA6101A2 EVM Schematic Diagram IN1 VO1 VDD VO2 BYPASS GND SHUTDOWN IN2 C3 1 F C1 0 1 F 8 7 6 5 1 2 3 4 ROUT LOUT RIN...

Page 16: ...05Z010 C5 Capacitor 10 F 6 3 V SMD A 1 Panasonic ECS TOJY106R Digi Key PCS1106CT ND R1 Resistor 100 k 1 16 W 5 SMD 0603 4 Panasonic ERJ 3GSYJ104 Digi Key P100KGTR ND S1 SHUT DOWN Switch momentary SMD...

Reviews: