VIM Control Registers
693
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Vectored Interrupt Manager (VIM) Module
19.9.17 Capture Event Register (CAPEVT)
and
describe this register.
Figure 19-45. Capture Event Register (CAPEVT) [offset = 78h]
31
23
22
16
Reserved
CAPEVTSRC1
R-U
R/WP-0
15
7
6
0
Reserved
CAPEVTSRC0
R-U
R/WP-0
LEGEND: R = Read only; WP = Write in privilege mode only; U = value is undefined; -
n
= value after reset
Table 19-22. Capture Event Register (CAPEVT) Field Descriptions
Bit
Field
Value
Description
31-23
Reserved
0
Reads are indeterminate and writes have no effect.
22-16
CAPEVTSRC1
Capture event source 1 mapping control. These bits determine which interrupt request maps to the
capture event source 1 of the RTI:
0
Interrupt request 0.
1h
Interrupt request 1.
:
:
7Fh
Interrupt request 127.
15-7
Reserved
0
Reads are indeterminate and writes have no effect.
6-0
CAPEVTSRC0
Capture event source 0 mapping control. These bits determine which interrupt request maps to the
capture event source 0 of the RTI:
0
Interrupt request 0.
1h
Interrupt request 1.
:
:
7Fh
Interrupt request 127.