SCI/LIN Control Registers
1706
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Serial Communication Interface (SCI)/ Local Interconnect Network (LIN)
Module
29.7.21 SCI Pin I/O Control Register 7 (SCIPIO7)
and
illustrate this register.
Figure 29-50. SCI Pin I/O Control Register 7 (SCIPIO7) (offset = 58h)
31
8
Reserved
R-0
7
3
2
1
0
Reserved
TX PD
RX PD
Reserved
R-0
R/W-n
R/W-n
R/W-n
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset, Refer to the Terminal Functions in the device datasheet for default pin
settings.
Table 29-38. SCI Pin I/O Control Register 7 (SCIPIO7) Field Descriptions
Bit
Field
Value
Description
31-3
Reserved
0
Reads return 0. Writes have no effect.
2
TX PD
Transmit pin pull control disable. This bit is effective in LIN or SCI mode. This bit disables pull control
capability on the input pin LINTX.
0
The pull control on the LINTX pin is enabled.
1
The pull control on the LINTX pin is disabled.
1
RX PD
Receive pin pull control disable. This bit is effective in LIN or SCI mode. This bit disables pull control
capability on the input pin LINRX.
0
Pull control on the LINRX pin is enabled.
1
Pull control on the LINRX pin is disabled.
0
Reserved
0
Writes have no effect.