FlexRay Module Registers
1329
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
26.3.2.1.2 ECC Diagnostic Status Register (ECCDSTAT)
ECC Diagnostic Status Register holds the ECC single-bit error and the double-bit error flags when in
diagnostic mode. A flag is cleared by writing a 1 to it.
and
illustrate this register.
NOTE:
In normal operation mode, double-bit errors are indicated in the Message Handler Status
(MHDS) register, except for FTU RAM. A double-bit error in FTU RAM is indicated by the
dedicated ECC error flag (PE) in the Transfer Error Interrupt Flag (TEIF) register.
Figure 26-110. ECC Diagnostic Status Register (ECCDSTAT) [offset_CC = 04h]
31
24
Reserved
R-0
23
22
21
20
19
18
17
16
DEFH
DEFG
DEFF
DEFE
DEFD
DEFC
DEFB
DEFA
R/W1C-0
R/W1C-0
R/W1C-0
R/W1C-0
R/W1C-0
R/W1C-0
R/W1C-0
R/W1C-0
15
8
Reserved
R-0
7
6
5
4
3
2
1
0
SEFH
SEFG
SEFF
SEFE
SEFD
SEFC
SEFB
SEFA
R/W1C-0
R/W1C-0
R/W1C-0
R/W1C-0
R/W1C-0
R/W1C-0
R/W1C-0
R/W1C-0
LEGEND: R/W = Read/Write; R = Read only; W1C = Write 1 to clear; -
n
= value after reset
Table 26-90. ECC Diagnostic Status Register (ECCDSTAT) Field Descriptions
Bit
Field
Value
Description
31-24
Reserved
0
Reads return 0. Writes have no effect.
23
DEFH
ECC Double-Bit Error Flag for FTU RAM.
0
No ECC double-bit error is detected.
1
ECC double-bit error is detected and diagnostic mode is enabled.
22
DEFG
ECC Double-Bit Error Flag for FlexRay Message RAM.
0
No ECC double-bit error is detected.
1
ECC double-bit error is detected and diagnostic mode is enabled.
21
DEFF
ECC Double-Bit Error Flag for Transient Buffer B RAM.
0
No ECC double-bit error is detected.
1
ECC double-bit error is detected and diagnostic mode is enabled.
20
DEFE
ECC Double-Bit Error Flag for Transient Buffer A RAM.
0
No ECC double-bit error is detected.
1
ECC double-bit error is detected and diagnostic mode is enabled.
19
DEFD
ECC Double-Bit Error Flag for Output Buffer 2 RAM.
0
No ECC double-bit error is detected.
1
ECC double-bit error is detected and diagnostic mode is enabled.
18
DEFC
ECC Double-Bit Error Flag for Output Buffer 1 RAM.
0
No ECC double-bit error is detected.
1
ECC double-bit error is detected and diagnostic mode is enabled.
17
DEFB
ECC Double-Bit Error Flag for Input Buffer 2 RAM.
0
No ECC double-bit error is detected.
1