EDMA Transfer Parameters
6-13
EDMA Controller
6.6
EDMA Transfer Parameters
Depending on the parameter options associated with a transfer, the
source/destination address, element/array/frame count can be updated by the
EDMA. The following sections describe the various parameters shown in
Table 6–3.
6.6.1
Options Parameter
The options parameter in the EDMA channel/event entry is a 32-bit field as
shown in Figure 6–8.
Figure 6–8. Options Bit-Fields
31 29
28 27
26
25 24
23
22 21
20
19 16
15 2
1
0
PRI
ESIZE
2DS
SUM
2DD
DUM
TCINT
TCC
rsvd
LINK
FS
RW, +0
RW, +0
RW, +0
RW, +0
RW, +0
RW, +0
RW, +0
RW, +0
R,+0
RW,+0
RW,+0
Table 6–3. EDMA Channel Options Field Description
Field
Description
Section
FS
Frame synchronization
FS=0; Frame sync is not needed to start a frame
transfer.
FS=1; Frame synchronization enabled. The relevant
event for a given EDMA channel is used to synchronize
a frame.
6.7
LINK
Linking events
LINK=0; Linking of event parameters disabled
LINK=1; Linking of event parameters enabled. Allows
reloading of event parameters from the parameter
RAM. Link address must be aligned on a 24-byte
boundary.
6.6.7 and
6.9
TCC
Transfer complete code
TCC=0000b to 1111b; 4-bit code is used to set the
relevant bit in CIPR (i.e. CIPR[TCC] bit) provided
TCINT=1.
6.13