TMP468EVM Software Overview
18
SBOU184B – November 2016 – Revised August 2019
Copyright © 2016–2019, Texas Instruments Incorporated
TMP468EVM and TMP468QFNEVM
4.2.4.3.2
Remote1-8
Temperature Reading
: displays the temperature of the channel
THERM Limit
: this slider sets the THERM limit threshold
THERM2 Limit
: this slider sets the THERM2 limit threshold
Remote Offset
: this number spinner will set the temperature offset of the remote channel temperature
reading
N-Factor Correction
: this number spinner is used to adjust for the N-factor of the remote BJT. Set this
spinner to the N-factor of the remote BJT that is connected to the TMP468EVM
Enable
: this checkbox will enable this channel to calculate new temperature data during a conversion
cycle
4.2.5
Data Capture Tab
The Data Capture Tab is where the temperature readings as well as the set temperature thresholds will be
graphed.
Figure 24. TMP468EVM Basic Settings Tab
In the bottom-left of the Data Capture tab, there is a list of some device configurations that are also found
on the Basic Settings tab with the addition of the "SEND ONE SHOT" button. This button will enable only
when the conversion mode is set to "Shutdown." When this button is clicked, a One Shot command will be
sent to the device and a single temperature conversion will be done.