Using the TMP451EVM Software
Figure 5-5. TMP451 Configuration Register
5.2.4 Conversion Rate Register Tab
The Conversion Rate Register tab contains both the Conversion Rate register and the Digital Filter Control
register. Changing values in these registers automatically writes them.
shows the conversion
rate register codes. For the Digital Filter register there are three options, Disabled (default), Level 1, and
Level 2. This filter maintains a running average of 4 samples (level 1) or 8 samples (level 2).
Table 5-1. Conversion Rate Register Codes
Code
Conversion/Second
Time (Second)
0x00
0.0625
16
0x01
0.125
8
0x02
0.25
4
0x03
0.5
2
0x04
1
1
0x05
2
500 m
0x06
4
250 m
0x07
8
125 m
0x08
16
62.5 m
0x09
32
31.25 m
5.2.5 n-Factor Correction Tab
The TMP451 allows for a different n-factor value for converting remote channel measurements to
temperature.
shows the n-factor correction register codes.
18
TMP451EVM Software Overview
SBOU131 – June 2013
Copyright © 2013, Texas Instruments Incorporated