Texas Instruments TMAG5170 User Manual Download Page 20

www.ti.com

4

4

EVM Use Restrictions and Warnings:

4.1 EVMS ARE NOT FOR USE IN FUNCTIONAL SAFETY AND/OR SAFETY CRITICAL EVALUATIONS, INCLUDING BUT NOT

LIMITED TO EVALUATIONS OF LIFE SUPPORT APPLICATIONS.

4.2 User must read and apply the user guide and other available documentation provided by TI regarding the EVM prior to handling

or using the EVM, including without limitation any warning or restriction notices. The notices contain important safety information
related to, for example, temperatures and voltages.

4.3

Safety-Related Warnings and Restrictions:

4.3.1

User shall operate the EVM within TI’s recommended specifications and environmental considerations stated in the user
guide, other available documentation provided by TI, and any other applicable requirements and employ reasonable and
customary safeguards. Exceeding the specified performance ratings and specifications (including but not limited to input
and output voltage, current, power, and environmental ranges) for the EVM may cause personal injury or death, or
property damage. If there are questions concerning performance ratings and specifications, User should contact a TI
field representative prior to connecting interface electronics including input power and intended loads. Any loads applied
outside of the specified output range may also result in unintended and/or inaccurate operation and/or possible
permanent damage to the EVM and/or interface electronics. Please consult the EVM user guide prior to connecting any
load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.
During normal operation, even with the inputs and outputs kept within the specified allowable ranges, some circuit
components may have elevated case temperatures. These components include but are not limited to linear regulators,
switching transistors, pass transistors, current sense resistors, and heat sinks, which can be identified using the
information in the associated documentation. When working with the EVM, please be aware that the EVM may become
very warm.

4.3.2

EVMs are intended solely for use by technically qualified, professional electronics experts who are familiar with the
dangers and application risks associated with handling electrical mechanical components, systems, and subsystems.
User assumes all responsibility and liability for proper and safe handling and use of the EVM by User or its employees,
affiliates, contractors or designees. User assumes all responsibility and liability to ensure that any interfaces (electronic
and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely
limit accessible leakage currents to minimize the risk of electrical shock hazard. User assumes all responsibility and
liability for any improper or unsafe handling or use of the EVM by User or its employees, affiliates, contractors or
designees.

4.4 User assumes all responsibility and liability to determine whether the EVM is subject to any applicable international, federal,

state, or local laws and regulations related to User’s handling and use of the EVM and, if applicable, User assumes all
responsibility and liability for compliance in all respects with such laws and regulations. User assumes all responsibility and
liability for proper disposal and recycling of the EVM consistent with all applicable international, federal, state, and local
requirements.

5.

Accuracy of Information:

To the extent TI provides information on the availability and function of EVMs, TI attempts to be as accurate

as possible. However, TI does not warrant the accuracy of EVM descriptions, EVM availability or other information on its websites as
accurate, complete, reliable, current, or error-free.

6.

Disclaimers:

6.1 EXCEPT AS SET FORTH ABOVE, EVMS AND ANY MATERIALS PROVIDED WITH THE EVM (INCLUDING, BUT NOT

LIMITED TO, REFERENCE DESIGNS AND THE DESIGN OF THE EVM ITSELF) ARE PROVIDED "AS IS" AND "WITH ALL
FAULTS." TI DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, REGARDING SUCH ITEMS, INCLUDING BUT
NOT LIMITED TO ANY EPIDEMIC FAILURE WARRANTY OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF ANY THIRD PARTY PATENTS, COPYRIGHTS, TRADE
SECRETS OR OTHER INTELLECTUAL PROPERTY RIGHTS.

6.2 EXCEPT FOR THE LIMITED RIGHT TO USE THE EVM SET FORTH HEREIN, NOTHING IN THESE TERMS SHALL BE

CONSTRUED AS GRANTING OR CONFERRING ANY RIGHTS BY LICENSE, PATENT, OR ANY OTHER INDUSTRIAL OR
INTELLECTUAL PROPERTY RIGHT OF TI, ITS SUPPLIERS/LICENSORS OR ANY OTHER THIRD PARTY, TO USE THE
EVM IN ANY FINISHED END-USER OR READY-TO-USE FINAL PRODUCT, OR FOR ANY INVENTION, DISCOVERY OR
IMPROVEMENT, REGARDLESS OF WHEN MADE, CONCEIVED OR ACQUIRED.

7.

USER'S INDEMNITY OBLIGATIONS AND REPRESENTATIONS.

USER WILL DEFEND, INDEMNIFY AND HOLD TI, ITS

LICENSORS AND THEIR REPRESENTATIVES HARMLESS FROM AND AGAINST ANY AND ALL CLAIMS, DAMAGES, LOSSES,
EXPENSES, COSTS AND LIABILITIES (COLLECTIVELY, "CLAIMS") ARISING OUT OF OR IN CONNECTION WITH ANY
HANDLING OR USE OF THE EVM THAT IS NOT IN ACCORDANCE WITH THESE TERMS. THIS OBLIGATION SHALL APPLY
WHETHER CLAIMS ARISE UNDER STATUTE, REGULATION, OR THE LAW OF TORT, CONTRACT OR ANY OTHER LEGAL
THEORY, AND EVEN IF THE EVM FAILS TO PERFORM AS DESCRIBED OR EXPECTED.

Summary of Contents for TMAG5170

Page 1: ...a complete bill of materials BOM Table of Contents 1 Trademarks 1 2 Overview 2 2 1 Kit Contents 2 2 2 Related Documentation From Texas Instruments 2 3 Hardware 3 3 1 Features 3 4 Operation 3 4 1 Quic...

Page 2: ...mentation From Texas Instruments This user s guide is available from the TI website under literature number SBAU350 Any letter appended to the literature number corresponds to the document revision th...

Page 3: ...int rotate and push module Detachable EVM for custom use cases Conveniently powered from a common micro USB connector 4 Operation 4 1 Quick Start Setup The following instructions describe how to set u...

Page 4: ...ownload and install this driver http www ti com lit zip sbac253 This is a one time step per computer Unzip the folder and run the exe file with administrator privileges 4 2 1 2 Firmware The GUI is cap...

Page 5: ...ints near PK1 and PK2 of the header pins see Figure 4 3 with a pair of tweezers or wire while pressing the RESET button Figure 4 3 Test Points Used to Enter DFU Mode Manually 2 With the MCU in DFU mod...

Page 6: ...GUI link provided above 3 To launch the GUI from the web browser click the GUI Composer application to open the GUI Composer window see Figure 4 4 Figure 4 4 GUI Composer Application Window a For fir...

Page 7: ...still does not connect make sure you are using the correct GUI EVM combination 3 Click the Registers icon shown in Figure 4 8 also available on the left side menu to view the register map and change d...

Page 8: ...r map set Auto Read to As fast as possible 3 Go to the Rotate Push tab inside the plots page see Figure 4 11 Figure 4 11 Rotate Push GUI Page 4 If the push button LEDs are not triggering at every angl...

Page 9: ...x must be lower case For the above example the EVM would return the results in JSON format acknowledge rreg 0x0A register address 10 value 65488 evm_state idle Write register format wreg ADR VAL where...

Page 10: ...ufacturing EVM PCBs 5 1 Schematics Figure 5 1 and Figure 5 2 show the schematic of the EVM Figure 5 1 shows the circuitry for the EVM and Figure 5 2 shows the mechanical components included with the E...

Page 11: ...C165 GND_A1 VCC_A1 ALERT_A1 PN4_A1 PN5_A1 PD2_A1 PP1_A1 5V_A1 0 R2 0 R3 0 R4 0 R5 0 R6 0 R1 150 R7 VCC 5 ALERT 8 CS 4 MISO 3 MOSI 2 SCLK 1 TEST 7 GND 6 TMAG5170A1EDGKQ1 U1 GND_A1 VCC_A1 GND_A1 4 7k R...

Page 12: ...H5 Rotate PushModule MECH H4 D82DIA LOGO PCB Texas Instruments CE Mark LOGO PCB WEEE logo MECH H6 PC038 750 4500 SST 0598 C N IN Figure 5 2 Hardware Schematic Schematics PCB Layout and Bill of Materi...

Page 13: ...e PCB layers of the EVM Figure 5 3 Top View Figure 5 4 Top Layer www ti com Schematics PCB Layout and Bill of Materials SBAU388A SEPTEMBER 2021 REVISED FEBRUARY 2022 Submit Document Feedback TMAG5170U...

Page 14: ...View Figure 5 6 Bottom Layer Schematics PCB Layout and Bill of Materials www ti com 14 TMAG5170UEVM SBAU388A SEPTEMBER 2021 REVISED FEBRUARY 2022 Submit Document Feedback Copyright 2022 Texas Instrum...

Page 15: ...tml PC038 750 4500 SST 0598 C N IN Acxess Spring J1 J2 2 HDR12 NRPN062PARN RC Sullins Connector Solutions R1 R10 2 0 RES 0 5 0 1 W AEC Q200 Grade 0 0603 0603 CRCW06030000Z0EA Vishay Dale R2 R3 R4 R5 R...

Page 16: ...SCB which is now available independently from this device 2 Added TI SCB User s Guide links to the Related Documentation table 2 Changed Hardware section 3 Changed Firmware section 4 Changed hyperlin...

Page 17: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Page 18: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Page 19: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Page 20: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Page 21: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Page 22: ...change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and display of thes...