Texas Instruments TLV3601EVM User Manual Download Page 19

www.ti.com

5

8.

Limitations on Damages and Liability:

8.1

General Limitations

. IN NO EVENT SHALL TI BE LIABLE FOR ANY SPECIAL, COLLATERAL, INDIRECT, PUNITIVE,

INCIDENTAL, CONSEQUENTIAL, OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF THESE
TERMS OR THE USE OF THE EVMS , REGARDLESS OF WHETHER TI HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. EXCLUDED DAMAGES INCLUDE, BUT ARE NOT LIMITED TO, COST OF REMOVAL OR
REINSTALLATION, ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES, RETESTING,
OUTSIDE COMPUTER TIME, LABOR COSTS, LOSS OF GOODWILL, LOSS OF PROFITS, LOSS OF SAVINGS, LOSS OF
USE, LOSS OF DATA, OR BUSINESS INTERRUPTION. NO CLAIM, SUIT OR ACTION SHALL BE BROUGHT AGAINST TI
MORE THAN TWELVE (12) MONTHS AFTER THE EVENT THAT GAVE RISE TO THE CAUSE OF ACTION HAS
OCCURRED.

8.2

Specific Limitations.

IN NO EVENT SHALL TI'S AGGREGATE LIABILITY FROM ANY USE OF AN EVM PROVIDED

HEREUNDER, INCLUDING FROM ANY WARRANTY, INDEMITY OR OTHER OBLIGATION ARISING OUT OF OR IN
CONNECTION WITH THESE TERMS, , EXCEED THE TOTAL AMOUNT PAID TO TI BY USER FOR THE PARTICULAR
EVM(S) AT ISSUE DURING THE PRIOR TWELVE (12) MONTHS WITH RESPECT TO WHICH LOSSES OR DAMAGES ARE
CLAIMED. THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT.

9.

Return Policy.

Except as otherwise provided, TI does not offer any refunds, returns, or exchanges. Furthermore, no return of EVM(s)

will be accepted if the package has been opened and no return of the EVM(s) will be accepted if they are damaged or otherwise not in
a resalable condition. If User feels it has been incorrectly charged for the EVM(s) it ordered or that delivery violates the applicable
order, User should contact TI. All refunds will be made in full within thirty (30) working days from the return of the components(s),
excluding any postage or packaging costs.

10.

Governing Law:

These terms and conditions shall be governed by and interpreted in accordance with the laws of the State of Texas,

without reference to conflict-of-laws principles. User agrees that non-exclusive jurisdiction for any dispute arising out of or relating to
these terms and conditions lies within courts located in the State of Texas and consents to venue in Dallas County, Texas.
Notwithstanding the foregoing, any judgment may be enforced in any United States or foreign court, and TI may seek injunctive relief
in any United States or foreign court.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2019, Texas Instruments Incorporated

Summary of Contents for TLV3601EVM

Page 1: ...VM Pin Assignments for Evaluating TLV3601 4 Figure 3 2 EVM Pin Assignments for Evaluating TLV3603 4 Figure 5 1 TLV3601 EVM Quick Start Setup 6 Figure 5 2 Propagation Delay Rise Portion 7 Figure 5 3 Pr...

Page 2: ...mple to evaluate timing performance with different measurement tools The output of the TLV3601 allows for direct connection to a 50 terminated oscilloscope input or a high speed high impedance FET pro...

Page 3: ...Offset Voltage 5 pin TLV3601 and 6 pin TLV3603 SC 70 Package 0 0 0 0 Feedback VCC GND VEE VEE GND Attenuation OUT VCC or VEE LE HYST LE HYST Sense IN Sense IN IN IN Sense Hysteresis Termination TLV36...

Page 4: ...Feedback Figure 3 1 EVM Pin Assignments for Evaluating TLV3601 0 0 0 0 Pin 6 VCC GND VEE Pin 2 VEE GND Attenuation Pin 1 OUT VCC or VEE Pin 5 LE HYST LE HYST Sense IN Sense Pin 4 IN Pin 3 IN IN Sense...

Page 5: ...Speed Oscilloscope with 50 terminations High bandwidth FET probe SMA Cables adapters Be sure to have matched length cables for IN SENSE IN SENSE and OUT GND Barrel www ti com Recommended Equipment SN...

Page 6: ...wer supply output 2 Connect positive terminal supply to TP1 negative terminal to TP2 and GND to TP3 3 Ensure that cables connecting to IN SENSE and OUT are matched length and impedance Perform any des...

Page 7: ...ransitions The low to high propagation delay in Figure 5 2 was calculated to be 2 184 ns while the high to low propagation delay in Figure 5 3 was measured to be 2 155 ns Input Output Figure 5 2 Propa...

Page 8: ...IN have corresponding sense lines so that the inputs to the device can be terminated on the lines with 50 to an oscilloscope This allows the input signals to be observed with minimal loading and dist...

Page 9: ...an be rectified using oscilloscope settings A high speed probe may be used for measurement of the output but rise and fall times may be limited Attenuation OUT TLV360X R8 Figure 6 4 Output Side Block...

Page 10: ...is connected to VEE the device will hold the output state for as long as the pin remains connected to that voltage If the pin is connected to VCC the device will function normally with no hysteresis C...

Page 11: ...es Top Layer Signal Layer 1 Signal Layer 2 Bottom Layer Figure 7 1 Layers www ti com Layout Guidelines SNOU183 MAY 2021 Submit Document Feedback TLV3601EVM User s Guide 11 Copyright 2021 Texas Instrum...

Page 12: ...CC or VEE LE HYST LE HYST Sense IN Sense IN IN IN Sense Hysteresis Termination TLV360X Figure 7 2 Block Diagram Layout Guidelines www ti com 12 TLV3601EVM User s Guide SNOU183 MAY 2021 Submit Document...

Page 13: ...8 Schematic Figure 8 1 TLV3601 EVM Schematic www ti com Schematic SNOU183 MAY 2021 Submit Document Feedback TLV3601EVM User s Guide 13 Copyright 2021 Texas Instruments Incorporated...

Page 14: ...oard Edge End Launch Solder 0732511150 Molex Inc J8 0 Header 100mil 2x1 Gold TH 2x1 Header TSW 102 07 G S Samtec J9 0 Header 100mil 3x1 Tin TH Header 3 PIN 100mil Tin PEC03SAAN Sullins Connector Solut...

Page 15: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Page 16: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Page 17: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Page 18: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Page 19: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Page 20: ...are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and...

Reviews: