The TLV320AIC3109-Q1 audio codec is a mono version of the TLV320AIC3104 device, so the
configuration and control of the TLV320AIC3109EVM is made using the TLV320AIC3104EVM software.
Some features of the TLV320AIC3104EVM GUI will not be available for the TLV320AIC3109EVM,
detailed information about these features are included in the following sections. As the GUI is adapted for
the TLV320AIC3104 device, the names for the signal and internal channels are not the same in some
cases for the TLV320AIC3109. In general, the single channel of the TLV320AIC3109-Q1 corresponds to
the left channel of the TLV320AIC3104, being the only exception the single headphone output, that
corresponds to the right headphone output of the TLV320AIC3104.
indicates the relationship
between the GUI and TLV320AIC3109-Q1 signal and internal block names.
Table 5. TLV320AIC3109EVM and TLV320AIC3104 GUI
Signal Name Relation
Name
TLV320AIC3104 GUI
TLV320AIC3109EVM
Left ADC
ADC
Right ADC
not used
Left DAC
DAC
Right DAC
not used
Left AGC
AGC
Right AGC
not used
IN1L/LINE1L
IN1/LINE1
IN1R/LINE1R
IN2/LINE2
IN2L/LINE2L
not used
IN2R/LINE2R
not used
HPRCOM
HPCOM
HPROUT
HPOUT
HPLCOM
not used
HPLOUT
not used
TI recommends using only the features mentioned in this user's guide for the evaluation of the
TLV320AIC3109-Q1 audio codec; otherwise, the device could present unexpected behavior.
The following section discusses the details and operation of the EVM software.
NOTE:
For codec configuration, the TLV320AIC3109-Q1 block diagram located in
Q1 Automotive, Low-Power, 96-kHz, Mono Audio Codec
is a good reference to help
determine the signal routing.
4.1
Device Selection for Operation With TLV320AIC3109EVM
The software that is installed provides operation for several devices of the TLV320AIC310X family of
audio codecs. An initial window should appear that looks like
. For operation with the
TLV320AIC3109EVM, the user should select
AIC3104
from the pull-down menu and click
Accept
. The
program will take a few seconds to configure the software for operation before proceeding. A progress bar