Test Setup and Results
6
SLVUBD7 – May 2018
Copyright © 2018, Texas Instruments Incorporated
TLC6C5716-Q1 Evaluation Module
ADVANCE INFORMATION
2.3.2
Advanced Settings Page
The
Advanced Settings
page (
) provides more register configuration features. The GLOBAL
RESET button resets the TLC6C5716-Q1 internal registers, meaning all registers values are set to 0,
except the
Mask LED Error
bit is set to 1. The INITIALIZE ALL CH VALUES buttons turns on all channels
with 50% grayscale (GS), dot correction, and brightness control values. GS and dot correction channels
can be adjusted separately.
For APS TEST and LOD TEST, turn off all output channels first, then perform the test. For other
configurations, refer to
TLC6C5716-Q1 16-Channel, Full Diagnostics, Constant-Current LED Driver With
7-Bit Dot Correction and 12-Bit PWM Dimming
for details.
Figure 5. Advanced Settings Page
2.3.3
Device Cascading
Use J34 and J35 to connect two TLC6C5716-Q1 EVMs in cascading mode. Note that users should
remove J34 shunt during the cascading mode.