Test Results
74
JAJU324B – March 2015 – Revised July 2017
翻訳版
—
最新の英語版資料
http://www-s.ti.com/sc/techlit/TIDU832
Copyright © 2015–2017, Texas Instruments Incorporated
EMI/EMC
規格準拠、産業用温度範囲のデュアルポート・ギガビット・イーサネットの
リファレンス・デザイン
表
表
34. IEC-61000-4-5 Surge Test Results for TIDA-00204 (continued)
PHENOMENON
BASIC
STANDARD
LEVEL
TIDA-00204
CONNECTOR
UNDER TEST
PERFORMANCE
CRITERION
(1) (2)
COMMENT
Surge
IEC61000-4-5
±2-kV, 2-
Ω
/500-A
(20-m shielded
CAT7 Ethernet
cable)
RJ45 port 2
A
Exceeds IEC61800-3
Class A is considered when there are less than two consecutive UDP packet losses and no major drop in
network utilization. One UDP packet loss will be tolerated by the system, if the following UDP packet is
echoed back successfully. The test has been conducted with a UDP error packet test program at around
5% network bandwidth (see
To verify the number of packets lost the program during the surge tests, a UDP packet transfer was
launched on each Gigabit Ethernet port. Each surge voltage test level and Gigabit Ethernet port was
tested with two different software programs running on the laptop for analysis of throughput and packet
errors during a surge event.
Class A was claimed as there was no significant network utilization reduction, from the average of around
20% during the UDP packet throughput test. During the packet error test, the network utilization remained
5%. The total number of submitted packets during the surge event was 230,000 packets (1526 bytes
each). Only one packet was lost. Higher network utilization may yield more packet error losses; however,
this was not tested due to lack of test equipment.
図
図
68. IEC61000-4-5 ±2-kV Surge: Network Utilization With UDP Packet Error Test on Gigabit Ethernet Port