Texas Instruments TCAN1046V User Manual Download Page 3

GND

VCC

GND

GND

VIO

GND

0.1µF

C7

0

R17

0

R14

0

R19

0

R23

120

R5

120

R6

120

R18

120

R20

330

R16

330

R26

TP9

TP13

GND

GND

330

R4

330

R10

TP3

TP5

GND

J4

J9

GND

VIO

TP14

TP2

330

R29

10µF

C17

1µF

C18

0.1µF

C19

VCC

GND

VCC

VIO

24V

D1

1

2

3

4

5

6

7

8

9

10

11

12

J5

330

R30

10µF

C20

1µF

C21

0.1µF

C22

VIO

GND

24V

D2

GND

GND

TP15

TP16

TP6

TP1

TP10

TP7

5

4

1
2
3

6

J1

5

4

1
2
3

6

J7

0

R11

DNP

0

R25

DNP

0

R9

DNP

0

R1

DNP

60.4

R7

60.4

R3

60.4

R15

60.4

R21

100pF

C6

100pF

C1

GND

100pF

C15

100pF

C9

VIO

VIO

VIO

VIO

0.1µF

C13

DNP

GND

0.1µF

C14

DNP

GND

0.1µF

C8

DNP

0.1µF

C10

DNP

TP11

TP8

TXD1

1

GND

2

VCC

3

RXD1

4

GND

5

TXD2

6

RXD2

7

STB2

8

CANL2

9

CANH2

10

VIO

11

CANL1

12

CANH1

13

STB1

14

U1

TCAN1046VDRQ1

J4_STB1

CH1_L1

CL1_L1

CH2_B

CL2_B

CH1_B

CL1_B

T

P

1

4

_

S

T

B

2

J5_TX1

J5_RX1
J5_TX2

J5_RX2

CH2_L2

CL2_L2

VIO

GND

J1_TX1
J1_RX1

J1_TX2
J1_RX2

4.70k

R12

4.70k

R13

4.70k

R24

4.70k

R22

TP4

TP12

TP17

TP18

4.7µF

C4

4700pF

C12

4700pF

C3

Green

1

2

D4

Green

1

2

D3

0

R8

4.70k

R2

0

R28

4.70k

R27

1

2

3

4

100µH

L2

1

2

3

4

100µH

L1

J11

J10

J8

J6

J3

J2

GND

GND

GND

GND

GND

GND

GND

GND

www.ti.com

Introduction

3

SLLU296 – August 2018

Submit Documentation Feedback

Copyright © 2018, Texas Instruments Incorporated

TCAN1046V Evaluation Module

Figure 2

shows the EVM schematic.

Figure 2. EVM Schematic

Summary of Contents for TCAN1046V

Page 1: ...TCAN1046V This user guide explains the EVM configurations for basic CAN evaluation and various load and termination settings Contents 1 Introduction 2 2 EVM Setup and Operation 5 3 CAN EVM Configurat...

Page 2: ...components as well as both CAN interfaces on the device separately 1 2 CAN EVM The TCAN1046V EVM has simple connections to all necessary pins of the CAN transceiver device and jumpers where necessary...

Page 3: ...P GND 0 1 F C8 DNP 0 1 F C10 DNP TP11 TP8 TXD1 1 GND 2 VCC 3 RXD1 4 GND 5 TXD2 6 RXD2 7 STB2 8 CANL2 9 CANH2 10 VIO 11 CANL1 12 CANH1 13 STB1 14 U1 TCAN1046VDRQ1 J4_STB1 CH1_L1 CL1_L1 CH2_B CL2_B CH1_...

Page 4: ...he CAN2 bus Use in combination with J3 to represent the combined 60 CAN termination J7 6 pin header Used to monitor CANH and CANL on CAN2 GND connections available as well J8 2 pin jumper Used to plac...

Page 5: ...2 J5 Pin Definitions Pin Connection Description 1 GND Pin 2 and 5 of the transceiver GND 2 VCC Pin 3 of the transceiver VCC 3 GND Pin 2 and 5 of the transceiver GND 4 VIO Pin 11 of the transceiver VIO...

Page 6: ...routed to JMP6 JMP2 and TP8 2 1 11 Pin 5 JMP6 Configurations 4 Way Jumper If using separate I O inputs JMP6 is used to configure pin 5 to pullup to VCC pulldown to GND VRXD or VIO supply input or VRE...

Page 7: ...Footprints CAN1 Split Terminati on Footprints CAN2 J2 J3 J6 J8 R3 R7 R15 R21 C3 C12 Standard termination 120 shorted open N A N A N A 60 load electrical parameterics shorted shorted Split termination...

Page 8: ...e EVM is being used as a CAN node Each digital input or output pin has footprints allowing for series current limiting resistors default populated with 0 pull up or down resistors depending on pin use...

Page 9: ...L2 GND2 VIO BIAS UNIT VCC 10 9 Low Power Standby Bus Receiver Monitor 6 8 DOMINANT TIME OUT VIO OVER TEMP DRIVER WAKE UP LOGIC MONITOR MUX LOGIC OUTPUT MODE AND CONTROL LOGIC 4 5 UNDER VOLTAGE VIO BIA...

Page 10: ...set forth above or credit User s account for such EVM TI s liability under this warranty shall be limited to EVMs that are returned during the warranty period to the address designated by TI and that...

Page 11: ...the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain great...

Page 12: ...t the EVM user guide prior to connecting any load to the EVM output If there is uncertainty as to the load specification please contact a TI field representative During normal operation even with the...

Page 13: ...OST OF REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF...

Page 14: ...TI Resource NO OTHER LICENSE EXPRESS OR IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD...

Reviews: