Figure 3-12. Miscellaneous Control Section
3.5.2.4 Faults and Warnings Section
The top right buttons on this box serve as controlling and monitoring faults.
Clip enable route the clip detection bit to the warning pin. This is displayed as yellow LED on the EVM.
Thermal enable route the over-temperature warning bit to the warning pin. This is display as the same yellow
LED on the EVM.
Clear button clears all the faults and warnings.
Read button manually read the faults and warnings.
Figure 3-13. Faults and Warnings Section
Software Overview
14
TAS6424MS-Q1 EVM
SLOU542 – OCTOBER 2020