Installation
3. In the
User Variables
section of the dialog, scroll through the list to see whether the variable PPSI2C
shows. If the variable is not already listed, click the
New
button. If the variable name PPSI2C already
exists in the list, click on PPSI2C to select it, and then click the
Edit
button. The
Edit User Variable
window appears, as shown in
Figure 10. Edit User Variables Dialog
4. In the window shown in
, type "PPSI2C" as the
Variable name
(for new variables). The
Variable value
should be "36" for TAS5707/09 and "3A" for TAS5707A/09A. Click
OK
and close the
dialog boxes.
Verify if the correct I
2
C address is used by looking at the symbolization name printed on the device
installed in the EVM being used, as shown in
Figure 11. TAS5707A Installed on TAS5707EVM