Operation
2
Operation
This section describes how to operate the TAS2552EVM.
2.1
Quick-Start List for Stand-Alone Operation
Use the following steps when operating the TAS2552EVM stand alone or when connecting the EVM into
an existing circuit.
2.1.1
Power and Ground
Use the following steps to operate the EVM:
1. Verify that the external power sources are set to OFF.
2. Connect a 3.6-V supply to the VBAT terminal in the lower right corner of the EVM and the GND
terminal located to the left of the VBAT terminal.
3. Make sure the 5V-SEL jumper in the upper left corner is in the “USB” Position (the red box in
). Connect the USB cable to the EVM. This will supply power to required blocks of the EVM.
Figure 1. Power Connections
3
SLAU496A – February 2014 – Revised July 2015
TAS2552 EVM
Copyright © 2014–2015, Texas Instruments Incorporated