SN65HVD257 EVM Setup and Operation for Redundant (Parallel Networks)

www.ti.com

3.3

Using CAN Bus Protection and Filtering Configuration

The EVM also has component footprints for various protection schemes to enhance robustness for
extreme system-level EMC requirements.

Table 4

summarizes these options. Typical examples of for

these components are: CM choke (TDK ACT45B series and EPCOS B82789 series from 11µH to 100µH),
bus filter capacitors are typically 100pF or less, TVS diodes from the MMBZ series 27V or lower, varistors
such as the TDK AVR series).

Table 4. CAN Bus Protection and Filtering Configuration

Protection and Filtering

Footprint

Use Case

Population and Description

Bus 1

Reference

Direct CAN transceiver to bus

R7 and R11 populated with 0

Ω

(default

connection

population)

Series Resistors or

R7 and R11 or L1

Series resistance protection CAN

R7 and R11 populated with MELF resistor

Common Mode Choke

(common footprint)

transceiver to bus connection

as necessary for harsh EMC environment

L1 populated with CM choke to filter noise

CM choke (bus filter)

as necessary for harsh EMC environment

Filter noise as necessary for harsh EMC

Bus Filtering Caps

C2 and C5

Bus filter

environment. Filter caps may be used in
combination with L1 CM choke.

To add extra protection for system level
transients and ESD protection, use the

D1 and D2,

Transient Protection

Transient & ESD Protection

population option footprints D1 and D2 for

C2 and C7 or D7

TVS diodes, or C2 and C7 or D7 for
varistors.

Protection and Filtering

Footprint

Use Case

Population and Description

Bus 2

Reference

Direct CAN transceiver to bus

R31 and R35 populated with 0

Ω

(default

connection

population)

Series Resistors or

R31 and R35 or L2

Series resistance protection CAN

R31 and R35 populated with MELF resistor

Common Mode Choke

(common footprint)

transceiver to bus connection

as necessary for harsh EMC environment

L2 populated with CM choke to filter noise

CM choke (bus filter)

as necessary for harsh EMC environment

Filter noise as necessary for harsh EMC

Bus Filtering Caps

C22 and C25

Bus filter

environment. Filter caps may be used in
combination with L2 CM choke.

To add extra protection for system level
transients and ESD protection, use the

D4 and D5,

Transient Protection

Transient & ESD Protection

population option footprints D4 and D5 for

C22 and C25 or D6

TVS diodes or C22 and C25 or D6 for
varistors.

10

SN65HVD257 CAN EVM: Functional Safety and Redundant CAN Network

SLLU172 – August 2012

Submit Documentation Feedback

Copyright © 2012, Texas Instruments Incorporated

Summary of Contents for SN65HVD257

Page 1: ...d Filtering Configuration 10 3 4 Using Customer Installable IO Options for Current Limiting Pull up or down Noise Filtering 11 3 5 Using customer installable IO options for 3 3V IO 11 4 SN65HVD257 EVM...

Page 2: ...odes normal mode and silent mode selected on pin 8 The FAULT pin indicates TXD dominant time out RXD dominant time out thermal shut down and under voltage faults Figure 1 SN65HVD257 Basic Block Diagra...

Page 3: ...combine the RXD outputs of both branches During dominant bits low were the branches do not match the XOR the circuit outputs a logic high A small RC filter on the output eliminates false outputs due t...

Page 4: ...such as GND VCC TXD RXD CANH CANL S FAULT The EVM supports many options for CAN bus configuration It is pre configured with two 120 resistors that may be connected on the bus via jumpers a single resi...

Page 5: ...5 GND 1 TP8 RXD 1 TP1 GND 1 C17 DNI U1 SN65HVD257 TXD 1 GND 2 Vcc 3 RXD 4 FLT 5 CANL 6 CANH 7 S 8 C13 1uF R10 DNI R17 0 U5 SN65HVD257 TXD 1 GND 2 Vcc 3 RXD 4 FLT 5 CANL 6 CANH 7 S 8 R19 330 C1 DNI TP7...

Page 6: ...60 load for CAN transceiver parametric measurement JMP10 4 pin header Connection for access to transceiver 2 CAN bus output CANH2 CANL2 GND GND Connect 120 CAN termination to the bus Used in combinat...

Page 7: ...XDprime RXD Receive Data 7 GND GND 8 VCC Pin 3 of Transceiver VCC 9 S2 Pin 5 of Transceiver 2 Used for Mode control 10 FLT2 Pin 8 of Transceiver 2 Indicates fault with transceiver 2 11 GND GND 12 FLT3...

Page 8: ...MP1 and TP10 This output indicates a RXD DTO TXD DTO Thermal Shut Down or undervoltage fault with transceiver 1 3 1 7 FLT 2 FAULT pin 5 transceiver 2 JMP1 TP23 Pin 5 of transceiver 2 is the fault outp...

Page 9: ...y the split capacitance is in the range of 4 7nF to 100nF Keep in mind that this is the common mode filter frequency not a differential filter that will impact the differential CAN signal directly Tab...

Page 10: ...us filter environment Filter caps may be used in combination with L1 CM choke To add extra protection for system level transients and ESD protection use the D1 and D2 Transient Protection Transient ES...

Page 11: ...ode pin input from JMP1 or PU or S U1 Input R1 JMP2 R2 NA C1 JMP2 PD to S U1 R27 S Mode pin input from JMP1 or PU or S U2 Input R25 JMP2 R26 NA C21 JMP2 PD to S U2 FAULT3 is the combined RXD output fr...

Page 12: ...r 1 JMP3 may be used to route these signals to an external host processor or test system Make sure that the MODE JMP2 jumper settings are not conflicting with signals to JMP3 JMP2 transceiver 1 config...

Page 13: ...nsceiver 2 Ensure JMP7 and JMP8 are not configured to conflict if TP19 is used as the input connection 4 2 4 FLT2 Output JMP7 TP23 Pin 5 of transceiver 2 is the fault output of the transceiver This ou...

Page 14: ...2 JMP5 JMP10 Header 1x4 HDR_THVT_1X4_100 ANY ACT45B or B82789 series 17 2 L1 L2 DNI TDK EPCOS CM choke 18 4 R1 R16 R25 R40 4 7k 805 ANY R2 R3 R8 R15 R17 R20 R21 R26 19 11 0 805 ANY R27 R32 R39 20 4 R3...

Page 15: ...o handling the product This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI a...

Page 16: ...egulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided...

Page 17: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments SN65HVD257EVM...

Reviews: