background image

Precautions

2-2

Operation

2.1

Precautions

Power Supply Input Polarity and Maximum Voltage

Always ensure that the polarity and voltage of the external power
connected to V

CC

 power input connector J1, J2, and/or V

DD

 power

input connector J6 are correct. Overvoltage or reverse-polarity
power applied to these terminals can open onboard soldered-in
fuses and cause other damage to the platform, installed evaluation
modules, and/or the power source.

Inserting or Removing EVM Boards

Do not insert or remove EVM boards with power applied – damage
to the EVM board, the platform, or both may result.

Figure 2–1.

Quick Start Platform Map

Signal Conditioning

****CAUTION****

Do not insert or remove

EVM boards with power

applied

ICC

JP4

F1

VR1

R1

JP3

JP2

JP1

AC/DC

(J2)

VCC(J1)

D1

D2

D3

D4

J2

J3

J4

J5

AC/DC

In

VCC

In

+

J1

DC

SOURCE

LED1

VCC

LED2

VDD

R2

JP5

IDD

B1

U6

POWER

SUPPL

Y

U3

U4

U5

U1

U2

Audio

Power

Amps

On

Of
f

Conditioning

S2

J7

J8

Right

Out

Left

Out

+–

+

JP6

Mode

Mute

Spk(U2-U4)

JP8

J9

Left

Out

JP7

S3

HP

Source

U2-U4

U5

Polarity

Lo

Hi

HP(U5)

C3

C2

+

+

R3

R5

J10

Stereo

HP Out

TP1

GND

Plug-N-Play Audio Amplifier
Evaluation Platform
SLOP097 Rev. C.1

Stereo

In

Right

In

Left

In

J6

In/Out

VDD

F2

VR2

+

DC
Power
In/Out

Speaker
Output

Headphone
Output

Audio

Input 

Power

Input

Batt

C1+

Right

Out

On

Of
f

Pwr

S1

TEXAS

INSTRUMENTS

1997

R4

6a

1

3

6b

6b

6b

6b

8

9

10

9

2

4

5

Summary of Contents for SLOP343

Page 1: ...November 2000 Mixed Signal Products User s Guide SLOU086 ...

Page 2: ... this warranty Specific testing of all parameters of each device is not necessarily performed except those mandated by government requirements Customers are responsible for their applications using TI components In order to minimize risks associated with the customer s applications adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards ...

Page 3: ...tatement describes a situation that could potentially cause harm to you The information in a caution or a warning is provided for your protection Please read each caution and warning carefully Related Documentation From Texas Instruments TI Plug N Play Audio Amplifier Evaluation Platform literature number SLOU011 provides detailed information on the evaluation platform and its use with TI audio ev...

Page 4: ...ith the limits of computing devices pursuant to subpart J of part 15 of FCC rules which are designed to provide reasonable protection against radio frequency interference Operation of this equipment in other environments may cause interference with radio communications in which case the user at his own expense will be required to take whatever measures may be required to correct this interference ...

Page 5: ...lifier Evaluation Module Parts List 2 6 2 4 4 TPA741 MSOP EVM PCB Layers 2 7 Figures 1 1 The TI TPA741 Audio Amplifier Evaluation Module 1 3 2 1 Quick Start Platform Map 2 2 2 2 Quick Start Module Map 2 4 2 3 TPA741 MSOP EVM Connected for Stereo BTL Output 2 5 2 4 TPA741 MSOP EVM Schematic Diagram 2 6 2 5 TPA741 EVM PCB 2 7 2 6 TPA741 EVM Silkscreen 2 7 2 7 TPA741 EVM Top Layer 2 8 2 8 TPA741 EVM ...

Page 6: ...Running Title Attribute Reference vi ...

Page 7: ...TPA741 MSOP audio amplifier evaluation module SLOP343 It includes a list of EVM features a brief description of the module illustrated with a pictorial diagram and a list of EVM specifications Topic Page 1 1 Feature Highlights 1 2 1 2 Description 1 3 1 3 TPA741 EVM Specifications 1 3 Chapter 1 ...

Page 8: ...Evaluation module is designed to simply plug into the platform automatically making all signal control and power connections Platform provides flexible power options Jumpers on the platform select power and module control options Switches on the platform route signals Platform provides quick and easy audio input and output connections Platform Power Options Onboard 9 V battery External 5 V 15 V VC...

Page 9: ...e EVM to be plugged into the TI plug n play audio amplifier evaluation platform or to be wired directly into existing circuits and equipment when used stand alone The platform which has room for a pair of TPA741 MSOP evaluation modules is a convenient vehicle for demonstrating TI s audio power amplifier and related evaluation modules The EVMs simply plug into the platform which automatically provi...

Page 10: ...1 4 Introduction ...

Page 11: ...o existing circuits or equipment The platform switch and jumper settings shown in Table 2 1 are typical for the TPA741 MSOP EVM They cause the TPA741 amplifier IC on the EVM to shut down when a plug is inserted into platform headphone jack J10 Table 2 1 Typical TI Plug N Play Platform Jumper and Switch Settings for the TPA741 MSOP EVM EVM JP6 JP7 JP8 S2 S3 TPA741 Mute X Hi See Note 2 X Notes 1 X D...

Page 12: ... or both may result Figure 2 1 Quick Start Platform Map Signal Conditioning CAUTION Do not insert or remove EVM boards with power applied ICC JP4 F1 VR1 R1 JP3 JP2 JP1 AC DC J2 VCC J1 D1 D2 D3 D4 J2 J3 J4 J5 AC DC In VCC In J1 DC SOURCE LED1 VCC LED2 VDD R2 JP5 IDD B1 U6 POWER SUPPLY U3 U4 U5 U1 U2 Audio Power Amps On Off Conditioning S2 J7 J8 Right Out Left Out JP6 Mode Mute Spk U2 U4 JP8 J9 Left...

Page 13: ...2 X Notes 1 X Don t care 2 Set S2 to ON when signal conditioning board is installed in U1 set S2 to OFF when no signal conditioning board is installed Power supply 6 Select and connect the power supply a Connect an external regulated power supply set to a voltage between 2 5 V and 5 5 V to platform VDD power input connector J6 taking care to observe marked polarity or b Install a voltage regulator...

Page 14: ... C5 S1 R1 R2 C2 C1 R3 R4 C3 Due to the very small size of the MSOP IC package the standard part number TPA741 is replaced with the code TIAJD Power supply 1 Ensure that all external power sources are set to off 2 Connect an external regulated power supply set to 5 V to the module VDD and GND pins taking care to observe marked polarity Inputs and outputs 3 Ensure that the signal source level is set...

Page 15: ...igh Right 5 VDC Audio Input Right 5 VDC GND Left OUT IN IN VDD GND U1 Shutdown R5 OUT GND C4 TEXAS INSTRUMENTS SLOP343 TPA741 MSOP EVM C6 C5 S1 R1 R2 C2 C1 R3 R4 C3 OUT IN IN VDD GND U1 Shutdown R5 OUT GND C4 TEXAS INSTRUMENTS SLOP343 TPA741 MSOP EVM C6 C5 S1 R1 R2 C2 C1 R3 R4 C3 Due to the very small size of the MSOP IC package the standard part number TPA741 is replaced with the code TIAJD ...

Page 16: ... Manufacturer Part Number Digi Key Number C4 Capacitor 10 µF 6 3 V A 1 Panasonic ECS TOJY106R Digi Key PCS1106CT ND C1 C2 C3 C5 Capacitor 1 µF 80 20 nonpolarized 0603 4 Murata GRM39 Y5V105Z10PT C6 Capacitor pad only 0603 0 R1 R3 R4 Resistor 20 kΩ 1 16 W 5 0603 4 Panasonic ERJ 3GSYJ203 R5 R2 Resistor 39 kΩ 1 16 W 5 0603 1 Panasonic ERJ 3GSYJ393 S1 Switch momentary 1 Panasonic P8048SCT ND Digi Key P...

Page 17: ... TPA741 MSOP EVM PCB Layers The following illustrations depict the TPA741 EVM PCB layers and silkscreen These drawings are not to scale Gerber plots can be obtained from ant TI sales office Figure 2 5 TPA741 EVM PCB Figure 2 6 TPA741 EVM Silkscreen ...

Page 18: ...TPA741 MSOP EVM PCB Layers 2 8 Operation Figure 2 7 TPA741 EVM Top Layer Figure 2 8 TPA741 EVM Bottom Layer ...

Reviews: