RTC_C Registers
829
SLAU356I – March 2015 – Revised June 2019
Copyright © 2015–2019, Texas Instruments Incorporated
Real-Time Clock (RTC_C)
20.3.24 RTCADOW Register – Calendar Mode
Real-Time Clock Day of Week Alarm Register – Calendar Mode
Figure 20-26. RTCADOW Register
7
6
5
4
3
2
1
0
AE
0
Day of week
rw
r-0
r-0
r-0
r-0
rw
rw
rw
Table 20-25. RTCADOW Register Description
Bit
Field
Type
Reset
Description
7
AE
RW
undefined
Alarm enable
6-3
0
R
0h
Always 0
2-0
Day of week
RW
undefined
Day of week (0 to 6)
20.3.25 RTCADAY Register – Hexadecimal Format
Real-Time Clock Day of Month Alarm Register – Hexadecimal Format
Figure 20-27. RTCADAY Register
7
6
5
4
3
2
1
0
AE
0
Day of month
rw
r-0
r-0
rw
rw
rw
rw
rw
Table 20-26. RTCADAY Register Description
Bit
Field
Type
Reset
Description
7
AE
RW
undefined
Alarm enable
6-5
0
R
0h
Always 0
4-0
Day of month
RW
undefined
Day of month (1 to 28, 29, 30, 31)
20.3.26 RTCADAY Register – BCD Format
Real-Time Clock Day of Month Alarm Register – BCD Format
Figure 20-28. RTCADAY Register
7
6
5
4
3
2
1
0
AE
0
Day of month – high digit
Day of month – low digit
rw
r-0
rw
rw
rw
rw
rw
rw
Table 20-27. RTCADAY Register Description
Bit
Field
Type
Reset
Description
7
AE
RW
undefined
Alarm enable
6
0
R
0h
Always 0
5-4
Day of month – high
digit
RW
undefined
Day of month – high digit (0 to 3)
3-0
Day of month – low
digit
RW
undefined
Day of month – low digit (0 to 9)