![Texas Instruments SimpleLink Ethernet MSP432E401Y Technical Reference Manual Download Page 818](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_1095578818.webp)
CAN Registers
818
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Controller Area Network (CAN) Module
11.4.11 CANIFnMSK2 Register [reset = 0xE0FF]
CAN IF1 Mask 2 (CANIF1MSK2), offset 0x02C
CAN IF2 Mask 2 (CANIF2MSK2), offset 0x08C
This register holds extended mask information that accompanies the CANIFnMSK1 register.
CANIFnMSK2 is shown in
and described in
.
Return to
Figure 11-15. CANIFnMSK2 Register
31
30
29
28
27
26
25
24
RESERVED
R-0x0
23
22
21
20
19
18
17
16
RESERVED
R-0x0
15
14
13
12
11
10
9
8
MXTD
MDIR
RESERVED
MSK
R/W-0x1
R/W-0x1
R-0x1
R/W-0xFF
7
6
5
4
3
2
1
0
MSK
R/W-0xFF
Table 11-18. CANIFnMSK2 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-16
RESERVED
R
0x0
15
MXTD
R/W
0x1
Mask Extended Identifier.
0x0 = The extended identifier bit (XTD in the CANIFnARB2 register)
has no effect on the acceptance filtering.
0x1 = The extended identifier bit XTD is used for acceptance
filtering.
14
MDIR
R/W
0x1
Mask Message Direction.
0x0 = The message direction bit (DIR in the CANIFnARB2 register)
has no effect for acceptance filtering.
0x1 = The message direction bit DIR is used for acceptance filtering.
13
RESERVED
R
0x1
12-0
MSK
R/W
0xFF
Identifier Mask. When using a 29-bit identifier, these bits are used for
bits [28:16] of the ID. The MSK field in the CANIFnMSK1 register are
used for bits [15:0] of the ID. When using an 11-bit identifier,
MSK[12:2] are used for bits [10:0] of the ID.
0x0 = The corresponding identifier field (ID) in the message object
cannot inhibit the match in acceptance filtering.
0x1 = The corresponding identifier field (ID) is used for acceptance
filtering.