![Texas Instruments SimpleLink Ethernet MSP432E401Y Technical Reference Manual Download Page 1576](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_10955781576.webp)
QEI Registers
1576
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Quadrature Encoder Interface (QEI)
24.5.2 QEISTAT Register (Offset = 0x4) [reset = 0x0]
QEI Status (QEISTAT)
This register provides status about the operation of the QEI module.
QEISTAT is shown in
and described in
Return to
Figure 24-5. QEISTAT Register
31
30
29
28
27
26
25
24
RESERVED
R-0x0
23
22
21
20
19
18
17
16
RESERVED
R-0x0
15
14
13
12
11
10
9
8
RESERVED
R-0x0
7
6
5
4
3
2
1
0
RESERVED
DIRECTION
ERROR
R-0x0
R-0x0
R-0x0
Table 24-4. QEISTAT Register Field Descriptions
Bit
Field
Type
Reset
Description
31-2
RESERVED
R
0x0
1
DIRECTION
R
0x0
Direction of Rotation. Indicates the direction the encoder is rotating.
0x0 = The encoder is rotating forward.
0x1 = The encoder is rotating in reverse.
0
ERROR
R
0x0
Error Detected.
0x0 = No error.
0x1 = An error was detected in the gray code sequence (that is, both
signals changing at the same time).