To J1.1
(IN1P)
INP
INM
To J1.3
(IN1M)
To J1.1
(IN1P)
INP
INM
Single-ended Input Test Setup
Short to MICBIAS
Differential Input Test Setup
Short to MICBIAS
Hardware Overview
12
SBAU341B – January 2020 – Revised June 2020
Copyright © 2020, Texas Instruments Incorporated
PCM6xx0Q1EVM-PDK Evaluation Module
2.2.3
Diagnostics Hardware Setup
The diagnostics test circuitry, as shown in
, is not connected to any channel by default. Connect
J32 and J34 to the INxP and INxM pins of the channel under test. With the onboard diagnostics test
circuitry, only one channel can be tested at a time. A fault is introduced by pressing SW1.
Figure 11. PCM6xx0Q1EVM Diagnostics Circuitry
The diagnostic test selection is done by populating a jumper on the pins of J33, but only install one jumper
at any one time. TI's recommended settings for this diagnostics test circuit are discussed in this section.
2.2.3.1
Short to MICBIAS Setup
shows a short to the MICBIAS test. If using a single-ended input for the test channel, only
connect INxP.
Figure 12. Short to MICBIAS Diagnostic Test Setup