Public Version
PRCM Register Manual
www.ti.com
Table 3-178. CM_ICLKEN_WKUP
Address Offset
0x0000 0010
Physical Address
0x4800 4C10
Instance
WKUP_CM
Description
Controls the modules interface clock activity.
Type
RW
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
EN_GPT1
EN_WDT2
EN_GPIO1
RESERVED
RESERVED
RESERVED
RESERVED
EN_32KSYNC
Bits
Field Name
Description
Type
Reset
31:10
RESERVED
Write 0s for future compatibility. Read returns 0.
R
0x000000
9
RESERVED
Reserved for non-GP devices
RW
0x0
8:6
RESERVED
Write 0s for future compatibility. Read returns 0.
R
0x0
5
EN_WDT2
WDTIMER 2 interface clock
RW
0x0
0x0: WDTIMER 2 interface clock is disabled
0x1: WDTIMER 2 interface clock is enabled
4
RESERVED
Reserved for non-GP devices
RW
0x0
3
EN_GPIO1
GPIO 1 interface clock control
RW
0x0
0x0: GPIO 1 interface clock is disabled
0x1: GPIO 1 interface clock is enabled
2
EN_32KSYNC
32 kHz Sync Timer interface clock control
RW
0x0
0x0: 32k Sync Timer interface clock is disabled
0x1: 32k Sync Timer interface clock is enabled
1
RESERVED
Reserved for non-GP devices
RW
0x0
0
EN_GPT1
GPTIMER 1 interface clock control
RW
0x0
0x0: GPTIMER 1 interface clock is disabled
0x1: GPTIMER 1 interface clock is enabled
Table 3-179. Register Call Summary for Register CM_ICLKEN_WKUP
PRCM Functional Description
•
WKUP Power Domain Clock Controls
PRCM Basic Programming Model
•
CM_ICLKEN_ <domain_name> (Interface Clock Enable Register)
PRCM Register Manual
•
Table 3-180. CM_IDLEST_WKUP
Address Offset
0x0000 0020
Physical Address
0x4800 4C20
Instance
WKUP_CM
Description
WAKEUP domain modules access monitoring.This register is read only and automatically updated.
Type
R
494
Power, Reset, and Clock Management
SWPU177N – December 2009 – Revised November 2010
Copyright © 2009–2010, Texas Instruments Incorporated