Public Version
www.ti.com
Functional Restrictions
B.4
Functional Restrictions
through
describe the subsystems and modules that are present on the die but
have their full functionality restricted in a CUS package.
B.4.1 Camera Image Signal Processor
Some camera subsystem functions are not available in the CUS package:
•
In CSIPHY2 complex input/output (I/O), the following pads are not connected to the CUS package
balls:
–
csi2_dx0/ccpv2_dx0
–
csi2_dy0/ccpv2_dy0
–
csi2_dx1/ccpv2_dx1
–
csi2_dy1/ccpv2_dy1
Therefore, CSIPHY2 is not operational in CSI2 and CCP2 modes. CSIPHY2 can pass the parallel
camera interface signals.
•
CSIPHY1 is not functional in CSI2 and CCP2 modes. It can pass the camera parallel interface signals.
•
The CSI2A, CSI1/CCP2B, and CSI2C receivers cannot be used, because they cannot receive data
from CSIPHYs.
NOTE:
Cells highlighted in orange in
indicate camera subsystem pads that are not
accessible through any ball on a CUS package.
describes the pads, I/Os, and their primary functions.
Table B-1. Camera ISP I/O Description
Pad
I/O
(1)
Primary Function
cam_hs
I/O
Line trigger I/O signal
cam_vs
I/O
Frame trigger I/O signal
cam_fld
I/O
Field identification I/O signal
cam_pclk
I
Parallel interface pixel clock
cam_d[11:0]
I
Parallel mode: input data bits 0 to 11
cam_wen
I
External write-enable signal
cam_strobe
O
Flash strobe control signal
csi2_dx0
I
Serial CSI2 mode. Fully configurable pair.
csi2_dy0
I
Serial CSI2 mode. Fully configurable pair.
csi2_dx1
I
Serial CSI2 mode. Fully configurable pair.
csi2_dy1
I
Serial CSI2 mode. Fully configurable pair.
cam_xclka
O
External clock for the image-sensor module
cam_xclkb
O
External clock for the image-sensor module
(1)
I = Input, O = Output
CSIPHY1 complex I/O must be kept in OFF state and CSI2C receiver must be kept disabled.
CSIPHY2 complex I/O must be kept in OFF state and CSI2A receiver must be kept disabled.
See
, Camera ISP Basic Programming Model, in
, Camera Image Signal Processor.
B.4.2 Display Subsystem
The display serial interface (DSI) complex I/O module and DSI protocol engine are not supported in
devices in the CUS package. DSI complex I/O can pass the parallel interface and RFBI data signals.
3705
SWPU177N – December 2009 – Revised November 2010
OMAP36xx Multimedia Device in CUS Package
Copyright © 2009–2010, Texas Instruments Incorporated