![Texas Instruments OMAP36 Series Technical Reference Manual Download Page 3125](http://html.mh-extra.com/html/texas-instruments/omap36-series/omap36-series_technical-reference-manual_10946783125.webp)
Public Version
www.ti.com
McBSP Basic Programming Model
21.5 McBSP Basic Programming Model
This section describes the programming model of typical McBSP module and SIDETONE core
applications.
21.5.1 McBSP Core
CAUTION
For all descriptions in this section, the McBSPi.
XFULL_CYCLE
bit
and
the
[11]
RFULL_CYCLE
bit
are
their
reset
value
(XFULL_CYCLE
bit=0
and
RFULL_CYCLE bit=1).
21.5.1.1 McBSP Initialization Procedure
This procedure for reset/initialization can be applied in general when the Receiver or Transmitter has to be
reset during its normal operation, and also when the Sample Rate Generator is not used for either
operation.
shows the serial port initialization procedure for master mode.
3125
SWPU177N – December 2009 – Revised November 2010
Multi-Channel Buffered Serial Port
Copyright © 2009–2010, Texas Instruments Incorporated