Public Version
HDQ/1-Wire Use Cases and Tips
www.ti.com
Table 18-5. Registers Print for HDQ/1-Wire Interrupts Enable
Register Name
Address
Value
Value description
0x480B 200C
0x0000 0060
Enable Interrupts
18.6.1.6 Read and Write Operations
The Read and Write operations in HDQ mode are described in
.
Some write operations are needed to configure the BQ27000 gauge: for example, it is necessary to write a
COMMAND KEY (0xA9 or 0x56) in the Device Control Register of the gauge. For more information, see
the TI BQ27000 gauge specification.
2860
HDQ/1-Wire
SWPU177N – December 2009 – Revised November 2010
Copyright © 2009–2010, Texas Instruments Incorporated