Public Version
SCM Register Manual
www.ti.com
Table 13-160. CONTROL_DEBOBS_4
Address Offset
0x0000 01C0
Physical Address
0x4800 2430
Instance
GENERAL
Description
Select the set of signals to be observed for hw_dbg8, hw_dbg9
Type
RW
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
OBSMUX8
RESERVED
OBSMUX9
Bits
Field Name
Description
Type
Reset
31:23
RESERVED
Read returns reset value.
R
0x00
22:16
OBSMUX8
Select the set of signals to be exported for
RW
0x000
WKUPOBSMUX8
15:7
RESERVED
Read returns reset value.
R
0x00
6:0
OBSMUX9
Select the set of signals to be exported for
RW
0x000
WKUPOBSMUX9
Table 13-161. Register Call Summary for Register CONTROL_DEBOBS_4
SCM Functional Description
•
•
:
SCM Register Manual
•
:
Table 13-162. CONTROL_DEBOBS_5
Address Offset
0x0000 01C4
Physical Address
0x4800 2434
Instance
GENERAL
Description
Select the set of signals to be observed for hw_dbg10, hw_dbg11
Type
RW
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
OBSMUX10
RESERVED
OBSMUX11
Bits
Field Name
Description
Type
Reset
31:23
RESERVED
Read returns reset value.
R
0x00
22:16
OBSMUX10
Select the set of signals to be exported for
RW
0x000
WKUPOBSMUX10
15:7
RESERVED
Read returns reset value.
R
0x00
6:0
OBSMUX11
Select the set of signals to be exported for
RW
0x000
WKUPOBSMUX11
Table 13-163. Register Call Summary for Register CONTROL_DEBOBS_5
SCM Functional Description
•
•
:
SCM Register Manual
•
:
2600System Control Module
SWPU177N – December 2009 – Revised November 2010