MTIF Registers
631
SLAU367P – October 2012 – Revised April 2020
Copyright © 2012–2020, Texas Instruments Incorporated
Metering Test Interface (MTIF)
23.4.6 MTIFPCR Register (Offset = Ah) [reset = 0h]
MTIFPCR is shown in
and described in
Return to
Pulse Counter Value Register
Figure 23-10. MTIFPCR Register
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PCR
RH-
Table 23-11. MTIFPCR Register Field Descriptions
Bit
Field
Type
Reset
Description
15-0
PCR
RH
0
Pulse Counter value register. This register returns the count value
from the pulse counter.