MTIF Registers
627
SLAU367P – October 2012 – Revised April 2020
Copyright © 2012–2020, Texas Instruments Incorporated
Metering Test Interface (MTIF)
23.4.2 MTIFPGKVAL Register (Offset = 2h) [reset = 6900h]
MTIFPGKVAL is shown in
and described in
.
Return to
Pulse Generator Value Register
Figure 23-6. MTIFPGKVAL Register
15
14
13
12
11
10
9
8
PGPW
R/W-69h
7
6
5
4
3
2
1
0
RESERVED
KVAL
R/W-0h
R/W-0h
Table 23-7. MTIFPGKVAL Register Field Descriptions
Bit
Field
Type
Reset
Description
15-8
PGPW
R/W
69h
PG password. Always reads as 0x69. Must be written as 0x5A for
register changes to be effective. This password differs from the pin
configuration and pulse counter passwords.
Reset type: PUC
5Ah (W) = PGPW : Must be written as 0x5A for register changes to
be effective.
69h (R) = PGPW_R : Read value while locked
7
RESERVED
R/W
0h
6-0
KVAL
R/W
0h
Pulse Count Number. This register value determines how many
pulses are generated withing 256 periods of the pulse grid
frequency(with password protection as in MTIFPGCNF).
MTIFPGCNF.PGEN has to be one to perform a change.
Reset type: PUC