How to Get Started
13
SNVU650 – May 2019
Copyright © 2019, Texas Instruments Incorporated
LP5012EVM User's Guide
3.3.4
Register Map
The register view appears when the Register icon in
is clicked. The register view provides the
register values, field values, and descriptions. The registers can be operated directly through the input
check box.
Figure 14. Register Map
Enter the desired hex value in the registers (Value column), perform a bit-wise configuration of any
register fields by double-clicking on the corresponding register bit, or configure a register field by entering
the desired value as hex in the Value column, binary in the Bits columns, or by using the input boxes for
each field under FIELD VIEW to set values for the corresponding variables. Field View displays the
description of all fields of the selected register. Each register can be read independently or all registers
can be read at once by using the Read Register or Read All Registers button, respectively. The data is
written to the registers in one of two ways, depending on the update mode (Immediate
↓
or Deferred
↓
)
button. Clicking the button toggles between the two modes. In Immediate mode, the register data is written
immediately following a Current Value , an individual bit, or a Value change. In Deferred mode, the
displayed data is written to all registers on depression of the Write Register button. Press the Read All
Registers button to read back all the registers and update the values in this table. If any register value
must be changed, simply double-click on the individual bit values to change the value in this table in
immediate updated mode or press the Write Register button to write all the registers at a time if Deferred
is selected instead of Immediate from the drop-down box. Register settings can be saved in text-file format
by selecting Save Registers from the file menu. A register settings file in text-file format can be loaded and
programmed automatically by selecting Load Register from the file menu.