Typical Measurement
www.ti.com
6
SNAU160E – March 2014 – Revised October 2017
Submit Documentation Feedback
Copyright © 2014–2017, Texas Instruments Incorporated
LMX2492EVM Evaluation Module
3
Typical Measurement
3.1
Default Configuration
3.1.1
Loop Filter
The parameters for the loop filter are:
Table 1. Loop Filter Configuration
PARAMETER
VALUE
VCO frequency
9.4 - 10.8 GHz
VCO gain
240 MHz/V
Effective charge pump gain
3.1 mA
Phase detector frequency
100 MHz
Loop bandwidth
435 kHz
Phase margin
60.8 degrees
C1_LF
68 pF
C2_LF
3.9 nF
C3_LF
150 pF
C4_LF
Open
R2_LF
390
Ω
R3_LF
150
Ω
R4_LF
0
Ω
Figure 5. Loop Filter
3.1.2
Typical Output
1. Follow
Section 2
to setup the evaluation.
2. Go to "USB communications"
→
"Write All Registers" to write all the registers to LMX2492.
Default output is 4.8 GHz at RFout/2 SMA connector.