4 Schematic
The bill of materials is tabulated in
shows the corresponding schematic.
Figure 4-1. LMQ61460EVM-400K Schematic
Note
Long leads and additional inductance in used to power the DC/DC may cause issues for ideal device operation. RD2, CD2, RD1, and CD1 are
placeholders for damping networks to be populated. For more information regarding this topic, reference the
EMI Filter Components and Their
Nonidealities for Automotive DC/DC Regulators Technical Brief
Schematic
SNVU698B – SEPTEMBER 2020 – REVISED DECEMBER 2020
LMQ61460EVM-400K User's Guide
7