![Texas Instruments LMG342XEVM-04X User Manual Download Page 20](http://html.mh-extra.com/html/texas-instruments/lmg342xevm-04x/lmg342xevm-04x_user-manual_1094645020.webp)
shows the LMG34XX-BB-EVM power and probe connection points.
Figure 8-2. Recommended Connection Points
PCB Notes:
• A: Probe points for gate drive logic
• B: 100-mil header for PWM input, PWM signals to LMG342XEVM-04X and FAULT output
• C: BNC connector for PWM input
• D: 12-V bias supply input
• E: FAULT protection option header
• F: Power stage high voltage input
• G: Probe point for power stage switch node
• H: Power stage high voltage output
To connect the LMG342XEVM-04X to the LMG34XX-BB-EVM:
1. Connect the oscilloscope or multimeter probes to the desired test points in A or G.
2. Connect the 12-V bias supply, connect load to output, and connect the input supply to input.
3. Connect the function generator to either the BNC connector PWM input at C or 100-mil header connector
input at pin 6 (PWM) and pin 5 (GND) at B.
4. Connect 12-V bias supply to the fan attached on the EVM, or enable an external fan to direct airflow across
the heat sink attached to the LMG342XEVM-04X.
Test Procedure When Paired With LMG34XX-BB-EVM
20
LMG342XEVM-04X User Guide
SNOU176A – OCTOBER 2020 – REVISED JANUARY 2022
Copyright © 2022 Texas Instruments Incorporated