Inductive Sensing GUI User’s Guide
3.10.3
Frequency Count
To display the raw frequency count output data instead of the inductance data, right click on the
Inductance plot and select "Toggle Data Type".
Figure 16. Switching Display Units between Inductance and Frequency Count
3.11 Saving and Loading
3.11.1
Configurations
Configurations can be saved and loaded. To save a configuration, click on the: "Save" icon in the toolbar.
Type a name for the file.
Figure 17. Save Icon
Configurations include all register names, current values, and default values. They are saved in Comma-
Separated Files (*.csv) and can be modified using a text or spreadsheet editor.
To load a configuration, click on the "Open" icon in the toolbar and select the configuration file:
Figure 18. Open Icon
3.11.2
Plot Data
Right-click a plot and select “Save Data…”
Data can be saved to a new file or an existing one. If an existing file is chosen, data will be appended.
14
LDC131x and LDC161x EVM User’s Guide
SNOU133 – December 2014
Copyright © 2014, Texas Instruments Incorporated