1. +VS to test point TP1
2. GND to test points TP11 AND TP12
3. OAV+ to test point TP2
4. Install jumper shunt on positions 2 and 3 on J1 and J2
5. Remove resistor R5 for REFA
a. Remove resistor R25 for REFB
6. Populate R1, R4, R6, and R7 with a 0-Ω resistor for channel A
a. Populate R18, R24, R26, and R27 with a 0-Ω resistor for channel B
7. Reference voltage to test point (TP13)
a. Reference voltage to test point (TP19)
8. Differential input signal connect to test points VinA– (TP14) and VinA+ (TP17) of channel A
a. Differential input signal connect to test points VinB– (TP20) and VinB+ (TP22) of channel B
9. Observe output at test point VOA (TP15)
a. Observe output at test point VOB (TP21)
Note
C15 and C22 are prepopulated with 0.1-µF power-supply decoupling capacitors. C22 is not required
to be removed for proper single-supply operation. See the respective device data sheet for additional
power-supply decoupling information.
Quick Start
INA-DUAL-2AMP-EVM
7
Copyright © 2021 Texas Instruments Incorporated