Introduction

 

The LM5017 Fly-Buck™ evaluation board provides multiple isolated outputs. By default 
it has 4 isolated outputs, while it is designed to be easily reconfigured as a dual output 
supply by changing the transformer. 

The board’s specifications are as follows: 

  Input voltage range: 17V to 32V, nominal 24V 

  Isolated outputs:  

o

  Quad output configuration: +/-15V@50mA, +/-5V@100mA 

o

  Dual output configuration 1: +/-5V@250mA 

o

  Dual output configuration 2: +/-15V@75mA 

  Switching frequency: ~260kHz 

  Board size: 2.2 inch x1.69 inch 

 

Figure 1 LM5017 Fly-Buck™ Evaluation Board 

 

 