1.12 Typical Connection and Test Equipment
The following is a list of typical test equipment that may be used to monitor the MIPI CSI-2 signals from
the DS90UB96X-Q1:
1. Logic Analyzer
2. Any SCOPE with a bandwidth of at least 4 GHz for observing differential signals.
3. UNH-IOL MIPI D-PHY Reference Termination Board (RTB)
4. UNH-IOL MIPI D-PHY/CSI/DSI Probing Board
5. UNH-IOL CSIGUI Tool
1.13 Termination Device
A termination device is required in order to properly monitor and measure the transmission of the MIPI
DPHY signals. The termination device should support the change of signals as it switches between LP
and HS modes. This can be provided by either a CSI-2 receiver or a dedicated dynamic termination board.
The recommended termination board is the UNH-IOL MIPI D-PHY Reference Termination Board (RTB).
1.14 Typical Test Setup
and
illustrate the typical test setups used to measure and evaluate DS90UB96X-
Q1.
Figure 1-21. Typical Test Setup for Application
The picture below shows a typical test set up using a video generator and logic analyzer.