2.11 Quick-Start Guide (SMBus Slave Mode)
Configure all devices to operate in the SMBus Slave Mode by setting their MODE pins to the L1 level, each
redriver is assigned a unique SMBus secondary address. This is accomplished by placing shunts as shown in
Table 2-11. SMBus/I2C Mode Shunt Configuration
SHNT#
HEADER
SHUNT ACROSS
PINS
1
J1 - J4
1-2
2
JMP7
1-2
3
JMP8
2-3
4
JMP17
2-3
5
JMP18
2-3
6
JMP19
2-3
7
J17
1-2, 3-4
8
J18
1-2, 3-4
9
J19
1-2, 3-4
10
J20
1-2, 3-4
11
J21
1-2, 3-4
12
JMP1
5-6
13
JMP2
3-4
14
JMP3
3-4
15
J30
9-10
16
J23
9-10
17
JMP4
7-8
18
JMP5
3-4
19
JMP6
3-4
20
J24
9-10
21
J25
9-10
22
JMP9
1-2
23
JMP10
1-2
24
JMP11
3-4
25
J26
9-10
26
J27
9-10
27
JMP14
3-4
28
JMP15
1-2
29
JMP16
3-4
30
J28
9-10
31
J29
9-10
1. Connect
or Aardvark Adapter to P4 (Note that the Adapter is not supplied with the
DS320PR412-421EVM). Install shunt on JMP17 across pins 1-2 for USB2ANY, 3-4 for Aardvark.
2. Install
Version 3.0.0.16 application and the DS320PR412-421 profile.
3. Plug the EVM into a PCIe x16 server motherboard slot. Ensure the motherboard is powered down before
installing the EVM or configured for hot-plug operation.
4. Install a compatible PCIe endpoint card into the straddle connector of the EVM.
5. Power-up the motherboard.
6. Start the SigCon Architect application.
7. Select the DS320PR412-421 Configuration Page and select the
Apply
box to enable the device profile. If
necessary, edit device addresses in the Edit Device Addresses box.
8. In the DS320PR412-421 High Level Page, select Block Diagram as shown in
.
Description
DS320PR412-421EVM User's Guide
11