Magnetic Field B (uT)
E
rr
o
r
(%
)
-500 -400 -300 -200 -100
0
100
200
300
400
500
-0.25%
-0.15%
-0.05%
0.05%
0.15%
0.25%
D002
Magnet Field B (uT)
Ou
tp
u
t V
o
lta
g
e
(
m
V
)
-500 -400 -300 -200 -100
0
100
200
300
400
500
-2500
-2000
-1500
-1000
-500
0
500
1000
1500
2000
2500
D001
EVM Operation
4.2.1
Laboratory Measurement Results
and
provide measured test results for linearity and error.
Figure 3. Output Voltage vs. Magnetic Field Strength
Figure 4. Error vs. Magnetic Field Strength
5
SLOU410A – September 2015 – Revised October 2015
DRV425 Evaluation Module
Copyright © 2015, Texas Instruments Incorporated