DLP LightCrafter 6500 and DLP LightCrafter 9000 EVM Flex Cable
21
DLPU028C – October 2014 – Revised November 2016
Copyright © 2014–2016, Texas Instruments Incorporated
DLP LightCrafter 6500 and 9000 Module Overview
1.7
DLP LightCrafter 6500 and DLP LightCrafter 9000 EVM Flex Cable
Electrical malfunctions can occur by stressing the flex cable(s) connecting the DMD circuit board to the
DLPC900 controller circuit board. Stressing the flex cable can be caused by:
•
Bending the cable outside the area identified in
(within 20.3 mm of connector plate centers).
•
Repeatedly bending the flex cable(s) where the bend radius is less than 25.4 mm.
•
A single bending of the flex cable(s) where the bend radius is less than 6.35 mm.
Figure 1-9. Flex Cable Diagram
NOTE:
The minimum bend radius for forming flex cable (flexible) circuit is 6.35 mm
Use caution when bending the flex cable to not exceed bending guidelines explained above.