Test Procedure
5
Test Procedure
5.1
Line and Load Regulation and Efficiency Measurement Procedure
1. Ensure load is set to constant resistance mode and to sink 0 ADC.
2. Ensure a jumper is on J101 on the EVM to set the EVM at OFF position before VIN and V5VIN are
applied.
3. Increase VIN from 0 to 12 V. Using V1 to measure input voltage.
4. Increase V5VIN from 0 to 5 V. Using V2 to measure input voltage.
5. Remove the jumper on J101 to enable the controller.
6. Vary load from 0 to 15 ADC, VOUT should remain in load regulation.
7. Vary VIN from 12 to 19 V, VOUT should remain in line regulation.
8. Decrease load to 0 A.
9. Put a jumper to short J101 to disable the controller.
10. Decrease V5VIN to 0 V.
11. Decrease VIN to 0 V.
5.2
List of Testpoints
Table 2. Function of Each Testpoint
Testpoints
Name
Description
TP100
5V
5V supply
TP101
GND
GND for 5V supply
TP102
PGOOD
Power good
TP103
Vins
VIN supply
TP104
GND
GND for VIN supply
TP105
SW
Switch node
TP107
Vouts
VOUT sense
TP108
GNDS
GND sense
TP106
REFIN
REFIN (Vout Setting)
TP109
GSNS
Differential sensing (low)
TP110
VSNS
Differential sensing (high)
5.3
Equipment Shutdown
1. Shut down the load.
2. Put the jumper on J101.
3. Shut down V5VIN and VIN.