MII Management Register Descriptions
1442
SPRUHE8E – October 2012 – Revised November 2019
Copyright © 2012–2019, Texas Instruments Incorporated
M3 Ethernet Media Access Controller (EMAC)
19.7.3 Ethernet PHY Management Register 2 – PHY Identifier 1 (MR2) Register , address 0x02
The Ethernet PHY Management Register 2 – PHY Identifier 1 (MR2) register, along with MR3, provides a
32-bit value indicating the manufacturer, model, and revision information.
Figure 19-23. Ethernet PHY Management Register 2 – PHY Identifier 1 (MR2) Register
15
0
OUI[21:6]
R-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 19-22. Ethernet PHY Management Register 2 – PHY Identifier 1 (MR2) Register Field
Descriptions
Bit
Field
Value
Description
15-0
OUI[21:6]
Organizationally Unique Identifier[21:6]
161h
This field, along with the OUI[5:0] field in MR3, makes up the Organizationally Unique Identifier
indicating the PHY manufacturer.
19.7.4 Ethernet PHY Management Register 3 – PHY Identifier 2 (MR3) Register, address 0x03
The Ethernet PHY Management Register 3 – PHY Identifier 2 (MR3) register, along with MR2, provides a
32-bit value indicating the manufacturer, model, and revision information.
Figure 19-24. Ethernet PHY Management Register 3 – PHY Identifier 2 (MR3) Register
15
10
9
4
3
0
OUI[5:0]
MN
RN
R-0
R-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 19-23. Ethernet PHY Management Register 3 – PHY Identifier 2 (MR3) Register Field
Descriptions
Bit
Field
Value
Description
15-10
OUI[5:0]
Organizationally Unique Identifier[5:0]
2Dh
This field, along with the OUI[21:6] field in MR2, makes up the Organizationally Unique Identifier
indicating the PHY manufacturer.
9-4
MN
01h
Model Number
The MN field represents the Model Number of the PHY.
3-0
RN
0h
Revision Number
The RN field represents the Revision Number of the PHY implementation.