![Texas Instruments CC2533 User Manual Download Page 111](http://html.mh-extra.com/html/texas-instruments/cc2533/cc2533_user-manual_1094592111.webp)
Output Compare Mode
A compare output pin is initialized to the value listed in
when:
•
a value is written to
T1CNTL
(all Timer 1 channels)
•
0x7 is written to
T1CCTLn.CMP
(channel n)
Table 9-1. Initial Compare Output Values (Compare Mode)
Initial Compare Output
Compare Mode (
T1CCTLn.CMP
)
Set output on compare (000)
0
Clear output on compare (001)
1
Toggle output on compare (010)
0
Set output on compare-up, clear on compare down in up-down mode (011)
0
In other modes than up-down mode, set output on compare, clear on 0 (011)
0
Clear output on compare-up, set on compare down in up-down mode (100)
1
In other modes than up-down mode, clear output on compare, set on 0 (100)
1
0
Clear when equal T1CC0, set when equal
T1CCn
(101)
1
Set when equal T1CC0, clear when equal
T1CCn
(110)
111
SWRU191C
–
April 2009
–
Revised January 2012
Timer 1 (16-Bit Timer)
Copyright
©
2009
–