8. Set Network ID 

 

 

 
Push  the  joystick  down  to  display  the  screen 
shown above. This lets you set the ID of the node 
in  case  you  need  to  run  several  PER  tests 
simultaneously 

and 

you 

have 

multiple 

development kits. Leave this set to 1 for now.

 

9. Packet Length 

 

 

 
Push  the  joystick  down  to  display  the  screen 
shown  above.  This  lets  you  set  the  length  of  the 
packets  to  be  transmitted.  The  packet  length  will 
affect  the  measured  packet  error  rate.  Push  the 
joystick left or right to select the packet length you 
want to use. 

 

10. Number of Packets 

 

 

 
Push  the  joystick  down  to  display  the  screen 
shown  above.  This  lets  you  set  the  number  of 
packets  to be  transmitted. Set  this  to the  desired 
value using the joystick. 

 

11. Select RF Settings 

 

 

 
Push  the  joystick  down  to  display  the  screen 
shown  above.  This  lets  you  select  preset  RF 
configurations, including modulation and data rate 
Preset 0: 2-FSK, 2.4 kBaud 
Preset 1: 2-FSK, 10 kBaud 
Preset 2: MSK, 250 kBaud 
Preset 3: MSK, 500 kBaud 

 

12. Select Mode

 

 

 

 
Push the joystick down to display the screen 
shown above. Use the joystick to select master 
mode. The EB you have configured now will be 
the master in the PER test. 

 

13. Configure 2

nd

 EB 

 

 

 
Perform steps 3 through 11 on the second EB. 
Push the joystick down until you get the display 
shown above. Leave this EB in slave mode. 

 

14. Start PER 

 

 

 

Push  the  joystick  down  on  both  EBs,  and  the 
screen  shown  above  is  displayed.  Push  the 
joystick right on the slave EB first, and then push 
the joystick right on the master EB. The PER test 
will  start  when  the  two  nodes  have  successfully 
connected. 

15. Run PER Test 

 

 

 

The uppermost line of the LCD will show the PER 
for  packets  transmitted  from  the  slave  to  the 
master,  while  the  second  line  will  show  the  PER 
for  packets  transmitted  from  the  master  to  the 
slave.  
 
The  PER  test  will  end  when  the  number  of 
packets  you  selected  in  step  10  is  reached  or  if 
100 consecutive packets are lost.

 

16. References 

 

Please visi

www.ti.com

 and  

 

http://www.ti.com/tool/cc2500emk

 

 
 
Download  the  CC2500DK  User  Manual,  the 
SmartRF™ Studio software, examples, as well as 
datasheets,  reference  designs  and  application 
notes. 
 
You  will  also  find  a  lot  of  information  on  the  TI 
E2E forum at 

http://e2e.ti.com

 

 

We  hope  that  you  will  enjoy  working  with  the 
CC2500 device.

 

 
 
 

SmartRF

™ Studio 

 

1. Download and Install 

 
Before  connecting  the  EB  to  your  PC,  download 
SmartRF

™ Studio from 

www.ti.com/smartrfstudio

 

Install  the  program  and  follow  the  instructions  in 
the wizard.  
 
Connect  the  EB  with  a  CC2500EM  to  the  PC 
using the USB cable and install the USB driver as 
described in the manual.  

 

2. Launch SmartRF Studio 

 

 

 
Launch SmartRF Studio and double click on the 
highlighted CC2500 device icon to get complete 
control of the device from the PC.

 

3. Configure the Radio 

 

  

 

 
You can now configure the radio, run tests, export 
register  settings  and  run  link  tests  with  another 
CC2500  on  a  SmartRF04EB  connected  to  the 
PC. 

 

 

Reviews: