CC112X/CC1175
SWRU295C
Page 78 of 108
AGC_CFG0 - AGC Configuration
Bit no. Name
Reset
R/W Description
7:6
AGC_HYST_LEVEL
0x03
R/W AGC Hysteresis Level. The difference between the desired signal level and the actual
signal level must be larger than AGC hysteresis level before the AGC changes the front
end gain
00
2 dB
01
4 dB
10
7 dB
11
10 dB
5:4
AGC_SLEWRATE_LIMIT
0x00
R/W AGC Slew Rate Limit. Limits the maximum front end gain adjustment
00
60 dB
01
30 dB
10
18 dB
11
9 dB
3:2
RSSI_VALID_CNT
0x00
R/W Gives the number of new input samples to the moving average filter (internal RSSI
estimates) that are required before the next update of the RSSI value. The
signal will be asserted from the first RSSI update.
is available on a GPIO or
can be read from the
register
00
2
01
3
10
5
11
9
1:0
AGC_ASK_DECAY
0x03
R/W Controls decay steps in ASK/OOK mode
00
1/16 IIR decay
01
1/32 IIR decay
10
1/64 IIR decay
11
1/128 IIR decay