CC112X/CC1175
SWRU295C
Page 59 of 108
WOR_CFG1.EVENT1
WOR_EVENT1
t
Event1
[µs] (f
RCOSC
= 32 kHz)
000
4
125
001
6
187.5
010
8
250
011
12
375
100
16
500
101
24
750
110
32
1000
111
48
1500
Table 26: Event 1
Equation 21 gives the Event 1 timeout.
1
_
1
1
EVENT
WOR
f
t
RCOSC
Event
Equation 21: t
Event1
An
SRX
strobe is issued on Event 1 if t
Event1
is larger than the crystal start-up time. If t
Event1
is shorter
than the crystal start-up time (
not asserted when Event 1 occurs), the
is asserted.
Event 2 can used to autonomously take the system out of SLEEP at regular intervals to perform RC
oscillator calibration. This will improve the accuracy of the timer.
The Event 2 timing is programmed with an exponent value decoded by the
setting.
WOR_CFG0.EVENT2_CFG
WOR_EVENT2
t
Event2
[s] (f
RCOSC
= 32 kHz)
00
Disabled
01
15
~1
10
18
~8.2
11
21
~65.5
Table 27: WOR_EVENT2
t
Event2
is given by Equation 22.
RCOSC
EVENT
WOR
Event
f
t
2
_
2
2
Equation 22: t
Event2
All three events
16
can be monitored on the GPIO pins by setting
WOR_EVENT0/1/2 (54/55/56).
16
(56),
must be ≠ 00b